Ubiquiti SFP28 Module

25G fibre networking • Tanzania buying guide

Ubiquiti SFP28 Module

Connect compatible network equipment over fibre at up to 25 Gbps. Compare Ubiquiti’s short-range multimode and long-range single-mode optical transceivers, choose the right fibre and confirm your port requirements before requesting a quotation.

SFP28 form factorDuplex LC UPCSR or LR variants

The right module in one minute

The Ubiquiti SFP28 Module range gives network designers a practical way to create fibre connections at up to 25 Gbps between compatible devices. For a short run inside a building or equipment area, choose the 25G Multi-Mode Optical Module, UACC-OM-SFP28-SR. For a longer fibre route, choose the 25G Single-Mode Optical Module, UACC-OM-SFP28-LR. These are distinct products with different fibre and distance requirements, not interchangeable versions of the same optical link.

Both Ubiquiti variants use an SFP28 form factor and a duplex LC UPC connection. Their published supported data rates are 1, 10 and 25 Gbps, although the speed that actually comes up depends on each host port, its configuration and the other end of the link. Before requesting a Tanzania quotation, identify your installed fibre, route length, device models and target speed. That information is more useful than ordering a transceiver by connector shape alone.

SR: multimode

UACC-OM-SFP28-SR
850 nm
Up to 100 m OM4 / 70 m OM3

LR: single-mode

UACC-OM-SFP28-LR
1310 nm
Up to 10 km

Verified technical specifications

Use this comparison to determine which version matches your fibre. Figures below are published by Ubiquiti for the exact model shown; a complete link must also meet the conditions of the host devices and installed cable.

Specification 25G SR (multimode) 25G LR (single-mode)
Manufacturer model UACC-OM-SFP28-SR UACC-OM-SFP28-LR
Fibre medium Multimode Single-mode
Form factor SFP28 SFP28
Connector Duplex LC UPC Duplex LC UPC
TX/RX wavelength 850 nm / 850 nm 1310 nm / 1310 nm
Supported data rates 1 / 10 / 25 Gbps 1 / 10 / 25 Gbps
Published distance OM4: 100 m; OM3: 70 m Up to 10 km
Max module power 0.8 W 1.3 W
Ambient operating range 0°C to 70°C 0°C to 70°C
Pack option Single unit Single unit

Both product pages identify Class 1 laser optical equipment. Fibre cable is not included in the manufacturer’s store description. Hardware compatibility, accessories and all local commercial details should be reviewed for the actual deployment.

Start with the connection you need

Buy this type of module when you are connecting switches, aggregation equipment or another supported network endpoint over installed fibre. An optical transceiver fits into a suitable network port and converts the equipment’s electrical signalling into light for transmission through fibre. It does not create an internet service, provide a network port where one is absent or make a slower switch capable of 25G. Think of the transceiver as one component in an end-to-end link whose performance is determined by the least capable part.

Start your specification with four questions: Which devices must connect? How far apart are they along the actual cable route? Which fibre type is already installed or planned? What speed must the complete path support? The answers establish whether SR or LR is appropriate and whether the necessary switch interfaces are present. A purchase request that includes these details can be reviewed for suitability before modules or matching patch leads are selected.

SR and LR: select the correct optical variant

The short-range model UACC-OM-SFP28-SR is designed for multimode fibre. Ubiquiti specifies 850 nm transmit and receive wavelengths, a maximum of 100 metres on OM4, and a maximum of 70 metres on OM3. Those are published distance limits for the indicated cable classes, not promises for an arbitrary installation. A route that is inside the right distance still needs clean connectors, suitable patch panels and sufficient optical performance throughout the complete run.

The long-range model UACC-OM-SFP28-LR uses single-mode fibre and 1310 nm transmit and receive wavelengths. Ubiquiti specifies a supported cable distance of up to 10 kilometres. Long-range does not mean every installed fibre automatically qualifies. Confirm the physical route, splice and connector losses, endpoints and optical compatibility. For two-way connectivity, plan one appropriate transceiver at each endpoint unless the equipment and design explicitly call for a different arrangement.

Understand what SFP28 actually means

SFP28 identifies a compact transceiver interface commonly associated with 25 Gigabit Ethernet connections. The physical module slots into a network-device cage designed to accept that form factor. It is different from an RJ45 copper Ethernet connector and does not allow ordinary twisted-pair cable to be inserted in place of fibre. Although SFP, SFP+ and SFP28 may look similar, they serve different generations of network interfaces, so matching the shape is not a sufficient compatibility test.

Ubiquiti lists its SR and LR optical modules as compatible with SFP28, SFP+ and SFP interfaces and publishes 1/10/25 Gbps supported rates. However, the actual negotiated or configured link speed depends on the specific host devices at both ends. A switch with only a 10G port cannot supply 25G simply because a 25G-rated optic is inserted. Verify the port speed matrix, manufacturer guidance and software support for the exact hardware revision.

Inspect your existing fibre before choosing

A label on a cable jacket, a building cabling report or a fibre certification document can help identify whether your route is multimode or single-mode. Multimode classes such as OM3 and OM4 are not equivalent to single-mode cabling, and one should not be substituted for the other without redesigning the optical link. Check the complete path, including in-wall cabling, patch leads and any patch-panel jumpers. An OM4 backbone with an unsuitable section elsewhere is not a fully verified OM4 route.

If documentation is missing, arrange inspection or testing by personnel who can identify the installed fibre correctly. Record the measured route length rather than relying on straight-line distance between rooms or buildings. A cable often takes a longer route through risers, trays or conduits. Establishing cable type and route length early avoids ordering modules whose optical characteristics do not match the infrastructure you already own.

Plan a short-range multimode link

For a 25G connection over installed OM4 multimode fibre within Ubiquiti’s stated 100-metre limit, the SR model is the relevant optical choice. On OM3, the stated limit is 70 metres. These figures should be treated as boundaries for planning, not as excuses to ignore patch leads, panel transitions or fibre quality. A path approaching its distance limit warrants a particularly careful review of cable classification, cleanliness and measurement records.

Use duplex LC UPC connections compatible with the optical module and cabling system. The two strands provide separate transmit and receive paths. Keep the strand identification consistent at both ends, document which patch-panel ports are used and avoid tight bends or compressed cable bundles. For an existing campus or building installation, do not assume that every cable described informally as multimode is OM3 or OM4. The installed grade must be verified before selecting the SR version.

Plan a long-range single-mode link

The LR model is intended for single-mode fibre routes up to the manufacturer-stated 10-kilometre maximum. It is relevant when a 25G link must travel between equipment rooms or across a larger site and the approved physical infrastructure provides a continuous suitable fibre path. Measure the actual cable distance and confirm the total loss of the route rather than using a map estimate. The allowable distance alone does not describe every real-world optical condition.

Long fibre routes often contain extra patch points, splices or cross-connects. Ask the installer to document those components and test the route against a suitable design plan. Also verify permission to use any shared or third-party fibre. A long-range optic cannot replace legal access, operational handover or fibre provisioning. Include enough time in the project sequence for route testing, cross-connect identification and end-to-end acceptance before a production migration is scheduled.

Match both ends of the connection

An optical link is a system of two endpoints, two ports, compatible optics and a correctly connected fibre path. Start by identifying the manufacturer and precise model of each endpoint. Then check whether each port supports the desired speed and optic type. If one device is not Ubiquiti equipment, its own compatibility requirements are especially important. Do not interpret a physically fitting module as a guarantee that mixed-vendor endpoints will operate together.

Specify a consistent optical standard, cable medium and connector arrangement for the complete run. Document each end’s module model, port number and intended operating rate. At installation, verify that transmit from one side reaches receive on the other. Mismatched optical variants, incorrect port configuration or reversed fibre polarity can prevent a link from coming up even when all parts appear to fit correctly.

Use the correct network port

A port labelled SFP28 is the natural starting point for a planned 25G optical connection. Some equipment provides selectable 1G, 10G or 25G operation; other devices offer only particular rates on certain ports. Consult the specification for the exact switch or adapter model and confirm any configuration requirements. Ubiquiti’s Hi-Capacity Aggregation switch, for example, is documented with four 1/10/25G SFP28 ports, illustrating a relevant type of endpoint rather than promising compatibility with every UniFi model.

Check whether the chosen ports are already occupied and how the new connection affects the network design. Port count, available uplinks, link aggregation policy, VLAN handling and physical rack location may all matter. If the endpoints are connected through additional switches, ensure the path beyond the new fibre segment can carry the expected traffic. A high-speed physical link can be useful without every application immediately achieving 25 Gbps of throughput.

Real data rates versus advertised speeds

The quoted 25 Gbps figure is a supported physical link rate, not a promise that a file transfer, internet connection or application will always deliver 25 gigabits of useful payload per second. Protocol overhead, endpoint performance, storage speeds, traffic patterns, switch capacity and other network bottlenecks can all influence measured results. Where the host supports it, the same module family also lists 10G and 1G operation, but any fallback or manual speed selection should be confirmed for the exact devices.

Define success in terms of your actual application. A backup network may require a certain transfer window; a switch uplink may need capacity during peak use; a server interconnect may prioritise predictable latency and reliability. Use those requirements to decide whether 25G is warranted, how much headroom to leave and where measurements should be taken. Test a new link as part of the complete network rather than relying only on the port’s nominal speed.

Why the fibre connector matters

Both Ubiquiti optics use duplex LC UPC connectors. This means the patching arrangement must provide the correct LC connector type and two optical paths for a conventional duplex connection. Do not purchase an optic because an LC-looking plug appears close enough; inspect the connector specification and the cable assembly. UPC and APC polishing arrangements should not be treated as freely interchangeable. Incorrect mating can cause unacceptable loss or damage to connector surfaces.

Protect connector ends until the final installation. Use appropriate fibre inspection and cleaning procedures, especially when cables have been stored, handled or rerouted. Dirty end faces are a common practical cause of weak or unstable optical links. When working around powered optical equipment, never look directly into a transceiver or fibre end. The Ubiquiti optical modules carry a Class 1 laser warning, and normal installation practices still require safe handling.

Power use and equipment environment

Ubiquiti specifies maximum module power consumption of 0.8 W for the SR variant and 1.3 W for the LR variant. Both official specification pages list an ambient operating temperature range from 0°C to 70°C. These are properties of the optical modules, not a statement that a complete rack, switch or outside enclosure will function across that same range. The host device, its power supply and the installation environment have their own limits.

Plan adequate airflow for network equipment and consider dust, humidity, cooling and cable management in the intended location. Avoid treating the optical module as weatherproof equipment; its small form factor normally places it inside a supported network device. In an installation with fluctuating mains power, review continuity requirements for the entire network path, including switches and upstream equipment. A transceiver can be correctly specified while the system as a whole remains vulnerable to power interruptions or unsuitable enclosure conditions.

Map the fibre path before installation

A simple port-to-port diagram is one of the most useful documents for this purchase. Show endpoint A, endpoint B, the intended ports, optical module variant, fibre type, patch panels, cross-connects and overall route length. Include identifiers that a technician can read at the rack. For a redundant design, illustrate the primary and backup paths separately so it is clear whether they genuinely follow independent physical routes.

Ask the cabling team to provide the latest as-built record rather than assuming an older design drawing is still accurate. Changes to patch panels, fibre assignments and rack layouts can happen after a project is completed. When the route is understood, the correct optic choice becomes easier to defend and a future technician can troubleshoot quickly. Good documentation does not increase the headline link speed, but it can reduce avoidable installation errors and make maintenance much less disruptive.

Installation preparation: practical checklist

Before inserting a module, confirm that the order contains the intended SR or LR part, that the installation device is supported, and that the cable type and connectors match the design. Check the port is available and that any required configuration change is approved. Inspect the module and connectors for visible shipping or handling damage without touching optical contact surfaces. Keep unused dust caps until connection time and prepare labelled patch leads.

Coordinate with the network administrator when the change affects a live production environment. Save relevant settings and record current port states so a technician can distinguish pre-existing faults from a new installation problem. Decide what a successful test looks like and how the original connection would be restored if necessary. These are sensible implementation controls, not claims that a module swap will be interruption-free. Equipment-specific installation instructions should take priority over a generic process.

Connecting the module and fibre

Follow the host device manufacturer’s insertion procedure and observe appropriate electrical and optical safety guidance. After the correct module is installed in a suitable port, connect the matching duplex LC UPC fibre lead and ensure the other endpoint is prepared. Route the lead without sharp bends, tension or a pinch point at the rack door. Avoid forcing a connector or module into a slot that does not accept it smoothly.

Where the host supports status reporting, inspect the link indication and selected operating speed. Then verify connectivity and application traffic across the new path. A link light alone is not the final acceptance test. Confirm the far endpoint, expected VLAN or routing behaviour, any relevant security controls and the absence of obvious errors. Record the resulting configuration and cable identifiers so the deployment can be supported after the installation team leaves.

Commissioning and acceptance testing

Test the installed fibre and the actual network service separately. Optical testing helps establish that the physical path is suitable, while network testing checks that the connected devices can communicate at the expected rate and under the intended load. On a newly built route, request appropriate fibre test records from the installer. For a reused route, a fresh condition check may be valuable if earlier measurements are unavailable or the cabling has been changed.

During commissioning, inspect port error counters, link stability and configured speed over an observation period appropriate to the service. Run representative traffic rather than a single unqualified throughput test. Document whether both endpoints remain stable during normal operating activity. A change record should also identify any known constraints: a temporary lower-speed port, a future hardware upgrade or an untested standby path. Clear acceptance evidence is more useful than a generic statement that the fibre is working.

Troubleshooting a link that stays down

Start with the basics before replacing equipment. Confirm that both ports are enabled, each endpoint accepts the installed optic, and each module is the planned variant. Check that the fibre medium, distance and connectors match the specification. Then inspect patching and polarity, ensuring the transmit and receive paths are correctly paired. A wrong patch lead or reversed strand arrangement can look like a transceiver failure.

Use the device’s management interface to review link events and any available optical diagnostics, without assuming every platform exposes the same measurements. Check firmware and supported transceiver combinations using device-specific documentation. If a port reports an unexpected speed, compare its configured mode with the far end. When testing spare components, change only one variable at a time and record the result. This method helps isolate a cable fault, an unsupported optic or a configuration mismatch rather than concealing the underlying cause.

Troubleshooting intermittent fibre performance

A link that comes up but repeatedly drops requires a different investigation from a completely dark port. Review error counters and time-correlated events on both endpoints. Inspect patch lead movement, connector cleanliness, cable bends and any recent physical changes. Compare the symptoms with temperature or power events affecting the switch. In a longer route, ask for the relevant optical measurements to determine whether the installed path is within an appropriate operating margin.

Avoid immediately increasing transmit power, changing unrelated switch settings or replacing multiple components without a diagnostic plan. Where supported, test with a known-good compatible lead or optic and record the change. Consider traffic and device limitations when a complaint is about low application throughput rather than physical link flaps. Correctly identifying whether the issue is optical, interface-related or higher in the network stack makes corrective work safer and more efficient.

When 25G is worth the upgrade

A 25G uplink may be useful when consolidated switch traffic, storage replication, backup schedules or high-demand server connections have outgrown a 10G path. The justification should come from observed usage, growth plans and the actual topology. A 25G transceiver does not eliminate constraints elsewhere, so look at end-to-end port speeds, switching capacity, storage I/O and application behaviour. In some networks, link aggregation, a different topology or a broader equipment refresh will be more suitable.

Consider future operating costs alongside the optical module purchase. New ports, compatible patch leads, fibre certification, maintenance windows and troubleshooting time may be part of the total project. Where the existing fibre is suitable and the host devices already support 25G, a module-based approach can be straightforward to evaluate. Where the infrastructure is not ready, planning the dependency work first is usually a better result than purchasing optics that cannot yet be used.

Campus, office and equipment-room scenarios

Within an office building, the short-range version can be considered for a compatible 25G connection between two nearby network racks using verified OM3 or OM4 multimode fibre. In a campus environment with a suitable single-mode backbone, the LR version may be more relevant to a longer connection between buildings. The actual deployment still depends on the route distance, switch interfaces, optical compatibility and quality of the installed cable.

A server-room aggregation design may use several high-speed links to consolidate downstream traffic, while a storage-related design may focus on sustained transfers during maintenance or backup periods. These examples illustrate common reasons to evaluate SFP28 optics, not claims that any named application will automatically reach maximum link speed. A useful purchasing conversation connects the module selection to a diagram, an application requirement and a test plan rather than simply asking for the fastest available transceiver.

Short copper runs and other alternatives

Optical modules are not the only way to connect two SFP28-equipped devices. Ubiquiti also documents a 25G Direct Attach Cable, UACC-DAC-SFP28, in short copper lengths of 0.5, 1 and 3 metres. For equipment in the same rack or an adjacent position, a suitable direct attach solution can reduce the need for separate optical modules and fibre patch leads. Check the exact connector arrangement, cable length and device compatibility before choosing it.

Ubiquiti also offers an Uplink Cable family with different copper and fibre-based lengths, but it is a separate product category and must not be confused with these SR and LR transceivers. For installed building or campus fibre, an appropriate optical module generally addresses a different connectivity problem than a short rack cable. A practical comparison should include the existing infrastructure, required distance, port support, physical routing and maintenance approach, rather than relying on headline speed alone.

How SFP28 differs from 10G SFP+ and 100G QSFP28

SFP28 products in this discussion are associated with up to 25 Gbps per supported connection. A conventional 10G SFP+ optic addresses a different link-speed target, while 100G QSFP28 modules use a different form factor and connect to compatible 100G host ports. Do not assume a 100G optic can be placed into a 25G slot or that an SFP+ host will gain additional capacity from a higher-rated optical transceiver.

If your network includes several generations of hardware, document the actual speed capabilities of each device and the planned transition path. Ubiquiti publishes lower-speed support for these specific SR and LR modules, but installation success still depends on the host model and port implementation. Mixed-speed networks can be normal during upgrades; the important requirement is to select an approved operating mode for the particular link rather than treating optical transceivers as universal adapters.

Reliability and redundancy planning

A single high-capacity fibre link may carry more operational traffic than the older connection it replaces. Consider whether an outage would affect the whole site, a single department or a noncritical service. If the design needs redundancy, specify physically distinct fibre paths and appropriate network failover controls where possible. Two modules in the same switch, or two strands in one damaged cable, do not by themselves create independent end-to-end resilience.

Use monitoring suited to the host equipment and define who responds to link faults. Preserve interface and cable identifiers in the operations record. Keep an appropriate spare strategy if the connected service is important, but confirm the exact variant before ordering a spare: an SR multimode transceiver is not a drop-in substitute for an LR single-mode route. Reliability comes from the overall design, maintenance and recovery process as well as the optic itself.

Security and network-change considerations

An optical uplink transports network traffic; it does not replace VLAN design, access controls, routing policy, firewalls or other security measures. A newly added 25G connection should be reviewed with the same care as any new switch-to-switch or server-facing path. Confirm which segments are allowed across it and whether the intended trunk, aggregation or routed configuration matches the approved design.

Before a production change, identify management access, rollback steps and the responsible administrator. On a shared network, coordinate the work with application owners who may experience brief path changes. Update diagrams and port descriptions after commissioning. These controls help prevent confusion when a new high-capacity link changes how traffic moves through the network, and they remain important even when the optical transceiver itself is a simple modular component.

Maintain the installation over time

After deployment, retain the transceiver model, installation date, connected switch port and cabling route in your asset records. Label patch leads at both ends and use consistent names in network monitoring. If maintenance work requires disconnecting fibre, keep connectors protected from dirt and handle them according to the site’s optical-cabling procedures. Avoid repeatedly disconnecting a healthy production link for casual checks; plan inspections around actual maintenance needs.

When investigating a future issue, compare current status with the original acceptance results. Changes to device software, network configuration, patching, equipment location or air circulation may provide useful clues. A documented spare optic can support controlled fault isolation, but only when it matches the required fibre and endpoint requirements. Good record-keeping also helps with later moves or capacity upgrades because technicians can see exactly why SR or LR was selected.

Ordering information for Tanzania buyers

For a useful quote request, provide the intended Ubiquiti model: UACC-OM-SFP28-SR for supported multimode short-range connectivity, or UACC-OM-SFP28-LR for supported single-mode long-range connectivity. Include the number of endpoints, quantity of modules required, switch or adapter models, fibre type, estimated route length and whether matching patch leads are needed. A route drawing or recent fibre test record can make compatibility review more precise.

The product family is being described for buyers in Tanzania, but no local price, stock level, delivery service, warranty term, tax treatment or regulatory approval is claimed here. Those details should be confirmed for an actual quotation and the exact supplied item. Do not substitute an unrelated retailer’s SKU for the local listing. If a purchasing team needs an internal product identifier, keep it separate from the Ubiquiti manufacturer model until it has been verified against the exact listing data.

Pre-purchase decision summary

Choose SR when the existing path is confirmed OM3 or OM4 multimode fibre, the full route fits the stated limit for that grade, and the endpoints support the optic and desired speed. Choose LR when the path is suitable single-mode fibre, the design requires its longer reach and the complete route is within the relevant optical limits. Choose neither until the infrastructure is identified if the current fibre type is unknown, the host ports lack suitable support or the installed connection has not been evaluated.

When comparing quotations, check that the exact model and quantity are stated. Confirm whether any fibre patch leads, installation or testing services are separately quoted, and review commercial terms directly rather than inferring them from a technical page. The right module is not automatically the one with the longest range; it is the one that matches the measured link and project requirements. This decision-led approach helps avoid mismatch costs and unnecessary downtime.

Frequently asked questions

What is a Ubiquiti SFP28 optical module used for?

It is a compact optical transceiver used to establish a fibre-based network connection through a compatible host interface. The 25G SR and LR models are relevant to supported links between network equipment where the fibre medium and port capabilities match. It does not add a port or upgrade an incompatible host to 25G.

Is the SR module suitable for a 100-metre fibre link?

Ubiquiti specifies a distance of up to 100 metres for UACC-OM-SFP28-SR over OM4 multimode fibre. The corresponding stated distance on OM3 is 70 metres. Confirm the installed fibre grade and the complete route, including patching, before treating the link as suitable. A cable described merely as multimode is not enough information.

Can the LR version work over OM4 multimode fibre?

No such use should be assumed. UACC-OM-SFP28-LR is specified for single-mode fibre at a 1310 nm optical wavelength. For an OM3 or OM4 multimode path within the appropriate published distance, review the SR variant instead. Mixing fibre media and optical specifications is not a reliable way to extend or reuse a connection.

Will either module provide 25G in a 10G SFP+ switch?

No. The modules list support for 1, 10 and 25 Gbps operation, and Ubiquiti lists compatibility with several SFP-family interfaces, but the host device still determines its available interface speeds. A 10G-only port cannot become a 25G port through an optic change. Verify the exact device specification and configuration.

Do I need one or two modules for a connection?

For a conventional point-to-point duplex fibre link between two SFP28 interfaces, plan a compatible transceiver at both ends. The precise quantities and component choices depend on the endpoint hardware and approved network design. The fibre patch leads are separate items unless the actual quotation explicitly states otherwise.

What fibre connector is required?

Both the SR and LR product specification pages show a duplex LC UPC connector. Use matching, correctly installed fibre patch leads and check the polishing specification. Do not assume a connector with a similar appearance is equivalent. Cleanliness, patch polarity and the connector arrangement at both ends matter to the link.

Can these modules be used with non-Ubiquiti equipment?

A cross-vendor deployment needs validation against the other equipment maker’s optical compatibility guidance. The module may physically fit a port, but that alone does not prove software, speed or optical compatibility. Confirm both endpoints and the cable path before purchase, especially in a network combining several switch brands.

What should I check when the link light does not appear?

Verify port enablement, both module models, fibre type, strand polarity, connector condition and the configured speed at each endpoint. Inspect device logs and status information if available. Test systematically with known-good approved components rather than replacing everything at once. If the fibre route was recently changed, recheck cross-connect assignments.

Are the stated maximum distances guaranteed in my installation?

The values are official product specifications for the indicated fibre types, not a guarantee for every installed route. Cable condition, patch connections, splices and the overall optical design must still be considered. For important links, request suitable route test records and verify performance as part of commissioning.

How do I request the correct Tanzania quotation?

Specify the required Ubiquiti model, quantity, endpoint device models, fibre type, measured distance and intended speed. Ask the supplier to confirm the exact item, commercial terms and any separately needed patch leads or installation work. Local price, stock and delivery details should be confirmed in the actual offer rather than assumed from general technical product information.

Request a 25G SFP28 module quotation

Tell the FourTeck Tanzania team whether your requirement is SR multimode or LR single-mode, and share the device models, route length, installed fibre type and quantity. Request confirmation of the exact model, matching accessories and current commercial terms before purchase.

Next step: Request model and compatibility confirmation with a quotation.