Ubiquiti QSFP28 Module: Choose the Right 100G Optical Link

Planning a 100 Gbps fibre connection for a network upgrade in Tanzania? The Ubiquiti QSFP28 Module family provides optical choices for very different cable plants and distances. Select the specific optical module by checking the switch port at each end, the existing or planned fibre, the connector and polish type, and the measured link length. Three manufacturer-documented options are the SR4 multimode module for short runs, the PSM4 single-mode module for intermediate runs, and the LR4 single-mode module for longer links. They are not interchangeable merely because each uses a QSFP28 form factor. An MPO-connected SR4 cannot simply be substituted for an LC-connected LR4, and the PSM4 uses a different fibre type and connector polish from SR4. This guide explains the buying and deployment checks before a quote is requested. Share your exact switch models, route distance and fibre details with FourTeck Tanzania for assistance identifying the correct item; availability and pricing must be confirmed for the specific model.

SR4 · MultimodePSM4 · Single-modeLR4 · Single-mode

Fast specification checklist before you request a quote

  • Exact model and supported speed of the switch at both ends
  • Number and type of QSFP28 ports available
  • Installed fibre: OM3, OM4, OS1, OS2 or unknown
  • Measured route length including patch leads and panels
  • Required MPO UPC, MPO APC or duplex LC UPC connection
  • Optic at the far end, link count and any spare requirement
  • Whether the quotation must include cabling, testing or installation

If a specification is uncertain, label it as needing verification. Avoid ordering a generic module on connector appearance alone.

Compare Ubiquiti 100G QSFP28 optical models

The figures below are model-specific manufacturer specifications. They describe the optics, not the availability or price of any Tanzania listing. Maximum reach depends on the exact stated fibre type and a correctly engineered route.

Model Manufacturer identifier Fibre Connector Listed reach Wavelength Maximum power
SR4 UACC-OM-QSFP28-SR4 Multimode OM4 / OM3 MPO-12 Type B UPC 100 m OM4 / 70 m OM3 850 nm 2.5 W
PSM4 UACC-OM-QSFP28-PSM4 Single-mode OS2 / OS1 MPO-12 Type B APC 2 km OS2 / 500 m OS1 1310 nm 3.5 W
LR4 UACC-OM-QSFP28-LR4 Single-mode Duplex LC UPC Up to 10 km 1295 / 1300 / 1304 / 1309 nm 4 W

SR4 is also listed for 40 / 100 Gbps use, subject to host and endpoint support. PSM4 and LR4 are specified at 100 Gbps. Ubiquiti lists 0–70°C ambient operation for all three modules. Optical fibre cables are not included.

What a QSFP28 optical module actually does

A QSFP28 optical transceiver connects a compatible high-speed network port to a fibre-optic link. It converts the electrical signals used inside the switch into optical signals that travel through the fibre, then performs the reverse process at the receiving end. For a buyer, the important benefit is the ability to design a 100 Gbps network connection around the route that must be crossed rather than assuming that every high-speed uplink needs the same cabling. The optical module is only one part of that path. You still need a suitable port at each endpoint, matching or otherwise explicitly interoperable optics, the correct fibres and connectors, a properly installed patching route, and the right configuration on the devices. A QSFP28-shaped device should not be confused with SFP28, which is a different form factor commonly used for 25 Gbps links. Verify port type before selecting any accessory.

Choose the exact variant before asking for a price

The phrase Ubiquiti QSFP28 Module does not identify one unique optical specification. For the three 100G modules covered here, the manufacturer’s model identifiers are UACC-OM-QSFP28-SR4, UACC-OM-QSFP28-PSM4 and UACC-OM-QSFP28-LR4. Record the complete identifier because it determines fibre type, connector, planned reach and optical characteristics. An order for a generic 100G module may result in an optic that physically fits the cage but cannot connect to the installed patch leads. If you have a project drawing, an old transceiver label or a bill of materials, use it to confirm the exact model rather than guessing from a photograph. The same check matters when adding capacity to an operating rack, where the connector type may not be visible from outside the patch panel. A quotation should specify the exact variant and quantity, not simply the broad QSFP28 family name.

SR4: short multimode 100G links

The UACC-OM-QSFP28-SR4 is the short-reach option for a suitably built multimode link. Ubiquiti documents an MPO-12 Type B UPC connector, an 850 nm optical wavelength, a maximum power consumption of 2.5 W and a 100 Gbps application with 100 metres on OM4 fibre or 70 metres on OM3 fibre. Its current product specifications also list supported 40 and 100 Gbps data rates; a particular link speed still depends on the host port and matching endpoint. This is a sensible variant to evaluate when two racks, rows or network areas are already served by the correct multimode infrastructure. Do not assume that an existing two-fibre LC patch lead can be plugged into it. Before buying, confirm the MPO fibre assembly, the patch-panel presentation, the full channel length, correct polarity and a compatible optic at the far end. The stated maximum reach is not a substitute for inspecting the actual installed path.

PSM4: intermediate single-mode reach

The UACC-OM-QSFP28-PSM4 uses single-mode fibre with an MPO-12 Type B APC connector and a documented 1310 nm optical wavelength. Ubiquiti lists 100 Gbps operation, up to 2 km reach using OS2 fibre and a maximum power consumption of 3.5 W. The manufacturer’s product information additionally limits transmission to 500 metres when OS1 single-mode fibre is used. That OS1 versus OS2 distinction is especially relevant when reusing a fibre route installed years earlier. This module can fit designs that need greater reach than a short multimode run but do not need the maximum published LR4 distance. It is not a drop-in substitute for an SR4 MPO module: despite the similar-looking connector family, the media and APC versus UPC polish differ. Verify fibre type, connector type, polarity and optical peer before specifying PSM4, and budget for the correct patch assemblies if they are not present.

LR4: longer single-mode 100G links

The UACC-OM-QSFP28-LR4 is Ubiquiti’s 100G single-mode option with a documented reach of up to 10 km. It uses a duplex LC UPC interface rather than an MPO connector, with transmit and receive wavelengths listed as 1295, 1300, 1304 and 1309 nm. Ubiquiti specifies a maximum power consumption of 4 W. LR4 is worth considering where the network design crosses longer building-to-building or campus routes and a suitable duplex single-mode fibre path is available. Confirm that the two fibres and their LC terminations are correct and that the remote equipment supports the chosen optic. The nominal 10 km specification describes a supported distance under appropriate conditions, not a promise that any 10 km cable will work regardless of splices, dirty connectors or patch-panel loss. Inspect the optical channel and link budget as part of the purchase decision.

The comparison that matters most

Start with the installed medium rather than with the longest advertised reach. SR4 and PSM4 both use MPO-style connections but SR4 is multimode UPC and PSM4 is single-mode APC; they must not be confused. LR4 uses a two-fibre LC UPC connection and suits a different patching arrangement. All three are QSFP28 optical transceivers intended for high-capacity connections, yet their wavelengths, power consumption and cable requirements are different. An installer choosing on port shape alone can discover the mismatch only after the maintenance window has started. When comparing quotes, require the vendor to write the exact manufacturer model, optical medium, connector and maximum stated reach next to the proposed unit price. The cheapest module is not the least expensive installed solution if it demands re-terminating a fibre plant or replacing patch panels. Correct fit, channel design and maintenance simplicity deserve equal attention.

Check the actual switch ports

A device must have a suitable optical interface, and it is important to distinguish a 100G QSFP28 cage from a 25G SFP28 or 10G SFP+ slot. The UniFi Enterprise Campus Aggregation switch, for example, has manufacturer-documented 100G/40G QSFP28 ports; this illustrates the kind of hardware for which a QSFP28 accessory may be considered. It does not establish compatibility with every other switch or every port configuration. Check the exact model number, hardware revision, port operating modes, software version and any platform documentation before ordering. Also determine whether the port is allocated to an uplink, aggregation route or other network role. Do not rely on a seller’s broad phrase such as compatible with Ubiquiti without a supported endpoint combination. Where the far end is not UniFi equipment, validate the remote manufacturer’s optics policy and the actual transceiver pairing separately.

Confirm both ends of the circuit

An optical link is a two-ended system. Record the switch make and model on side A and side B, the port number and its supported speeds, and the transceiver intended for each side. Match the Ethernet optical application, fibre type, connector presentation and any applicable lane or polarity requirements. The two end modules do not become compatible simply because both advertise 100 Gbps. An SR4 optical interface and an LR4 optical interface use different physical transmission arrangements. Even when a module is correctly seated and recognised, the link can remain down if the remote optic, patch leads or port modes do not agree. If replacing only one failed optic, obtain the full identifier of the module still in service and confirm whether the replacement must match it. If designing a new route, specify the pair and cable assembly as one engineered link rather than as separate shopping items.

Measure the complete optical route

The switch-to-switch route includes more than the length printed on an outside-plant cable drum. Include patch leads at both ends, rack routing, cross-connects, fibre distribution panels, service loops, splices and the installed cable span. Confirm that the recorded figure is the actual optical-channel length rather than a straight-line distance between buildings. For SR4, compare that route against Ubiquiti’s documented OM4 and OM3 reaches. For PSM4, identify whether the path is OS2 or OS1 because the manufacturer’s stated limits differ. For LR4, verify that the full route remains inside the module’s stated distance and optical characteristics. For every variant, allow for connector cleanliness and the actual measured loss rather than using distance as the only criterion. A properly documented path reduces surprises during commissioning and helps maintain the connection later.

Audit an existing fibre installation

Existing fibre may make the project simpler, but only if the audit establishes what is installed. Read cable markings and as-built records, identify fibre type and count, inspect patch panels and verify the connector polish. Determine whether fibres are available end to end, whether any cores are already in use and whether a shared route creates an availability risk. If records are incomplete, ask a qualified fibre technician to test and label the path before specifying optics. An LC connector visible at a patch panel does not prove that the whole route is suitable for the selected 100G transceiver. Likewise, an MPO patch lead in a rack is not proof that the connector polarity, fibre mapping or polish is appropriate. Record the actual route, test results and proposed module variants together; that single document will help procurement, installation and future fault diagnosis.

Understand MPO versus duplex LC

The connector is a major purchasing decision, not a minor accessory detail. The Ubiquiti SR4 optical module specifies MPO-12 Type B UPC, while PSM4 specifies MPO-12 Type B APC; LR4 specifies duplex LC UPC. MPO provides a multi-fibre interface, and LC duplex presents a pair of fibre connections. UPC and APC refer to different connector end-face finishes, so they must not be treated as interchangeable. Ask the installer to confirm matching connector gender, polish and cable assembly arrangement where required, using the equipment and cabling documentation. If you purchase an MPO optic for a pre-existing LC duplex path, you may need a different network design rather than just a cheap adapter. If the final link must be LR4, plan for the proper duplex single-mode LC path from the beginning. Correct connector selection saves avoidable rework.

Treat fibre polarity as an engineering requirement

A multi-fibre system depends on the intended transmit and receive paths reaching the correct positions at the other end. That means an MPO jumper is not automatically suitable merely because it physically fits the module. Ubiquiti specifies Type B MPO connections for the SR4 and PSM4 models discussed here, but the full end-to-end assembly still needs to be checked against the transceiver and structured-cabling plan. Document the selected cable type, patch-panel method and both endpoint connections before the installation window. Avoid improvising with unverified adapters that may change polarity or connector presentation. For long-running networks, label the fibre pair or MPO route in an operationally meaningful way, noting the optical technology rather than only a cable number. A documented polarity scheme makes future moves, additions and replacements more reliable and shortens the time needed to trace a link that refuses to come up.

Separate port speed from network throughput

A 100 Gbps optical interface describes a nominal Ethernet link rate, not a guarantee that an application, server or internet connection will transfer useful data at that rate. Actual traffic results depend on the switching platform, port modes, packet overhead, traffic patterns, endpoint hardware and upstream bottlenecks. Before allocating budget to 100G optics, determine what traffic the link will carry and whether both endpoint systems can make use of the capacity. A campus aggregation uplink may be intended to carry many lower-speed access links, while a storage or compute path can have a different traffic profile. Ask whether the goal is higher peak bandwidth, fewer bottlenecks, more resilient uplinks or capacity for planned expansion. These questions inform both module choice and broader network design, and they prevent the misleading assumption that a transceiver alone upgrades the whole network.

Design for the actual topology

Draw the connection rather than beginning with a parts list. A point-to-point fibre link between two switches differs from a redundant pair of uplinks, a multi-building ring or a rack aggregation design. Identify the number of endpoints, how switches will be managed, which links are expected to carry active traffic and what happens if one path fails. Where a design uses link aggregation or redundant routing, confirm those features on the switches and configure them deliberately; a second optical module alone does not create resilience. Consider whether an alternative fibre path is physically separated from the primary route. A two-link design using the same underground duct may share the same failure mode. For procurement, the final topology determines module quantities, spare policy, patching and testing requirements. In practice, the best 100G purchase often starts with an agreed network diagram and a marked fibre route.

Plan for rack-to-rack connections

For high-capacity connections within a room or between nearby equipment racks, measure the true cable path including overhead trays and rack cable managers. Where the multimode type, channel length and MPO infrastructure support it, SR4 may be an appropriate optical option. Inspect the proposed termination location and leave manageable slack without violating cable bend-radius requirements. If the racks have no appropriate fibre path, compare the complete cost of installing the intended multimode run against other supported connectivity methods for the distance. Do not decide on an optic merely because the devices are geographically close; the route may pass through patch panels and cable-management systems that change the required cable length. Label each side with port and module information and record the tested condition before handing over the link. Short links still need correct handling and documented commissioning.

Plan for building-to-building connections

A cross-building link requires more attention to the route, cable quality and fault isolation than a short in-rack jumper. Where a suitable OS2 single-mode path exists and the end-to-end distance is within the documented limits, PSM4 or LR4 may be candidates, with connector and termination choice helping distinguish them. Assess whether the cable crosses buried ducts, aerial sections, shared pathways or third-party infrastructure. Fibre test records, physical protection, entry-point arrangements and accessible patch panels matter to maintainability. Do not assume that a module’s advertised optical reach establishes permission to use a route or removes the need for civil works, local building arrangements or network design approval. Where the intended link is mission-critical, record an alternative service strategy and a practical repair plan. The transceiver choice should follow the path and its operational constraints, not the other way round.

Use the right option for a data-centre aggregation link

Dense networks often concentrate many lower-speed connections into high-capacity uplinks. When evaluating a 100G QSFP28 optical module for such a role, assess the fibre type already available in the structured cabling plant, the aggregation switch’s QSFP28 port count, the supported link mode and the expected traffic concentration. The selected optic may be a small line item compared with switch ports, racks, trays and cabling, but choosing it incorrectly can delay the entire cutover. Account for available spare ports and planned future connections, not only today’s active circuit. Also review operating conditions and airflow at the switch. Confirm whether the planned migration can be performed in stages, whether the old link will remain available during testing and how the network team will verify traffic after the cutover. These operational questions are equally relevant to enterprise facilities and service networks in Tanzania.

Upgrading from 10G or 25G

Moving from an existing 10G or 25G uplink to 100G is not just a transceiver swap. A 10G SFP+ slot or 25G SFP28 slot is not a 100G QSFP28 port, so the switch hardware and the opposing device must be reviewed first. Confirm capacity, port support, software configuration, rack connectivity and the available fibre route. Existing duplex LC single-mode wiring may make LR4 worth examining, while existing multimode MPO infrastructure may make SR4 a more natural technical candidate; neither conclusion is automatic. Develop a rollback plan so the existing circuit can be restored if the new link does not meet acceptance criteria. Determine whether all intermediate equipment and interfaces need upgrades or whether a new aggregation layer can be introduced without disrupting access switches. Document dependencies before accepting the new optic’s commercial quotation.

Plan for resilience and maintenance

When a 100G link carries important production traffic, consider its failure consequences before focusing on bandwidth. Determine whether a spare optic should be held, whether an alternative route exists and which team owns patching and troubleshooting. Store replacement modules in suitable protective packaging and keep fibre connectors capped until installation. Retain the exact model identifiers for both endpoints so an emergency replacement request does not become a search for a generic QSFP28 item. Where redundancy is required, test the failover behavior during an agreed maintenance period rather than assuming that a second cable automatically creates a functioning backup. Keep the link diagrams and test records accessible to support staff. Reliable service is a combined result of appropriate optics, physical infrastructure, switch configuration, monitoring and operational processes; no single module can provide all of these by itself.

Allow for temperature, power and airflow

All three Ubiquiti 100G optical variants discussed here have a manufacturer-listed ambient operating temperature range of 0 to 70 degrees Celsius. Their maximum power figures differ: 2.5 W for SR4, 3.5 W for PSM4 and 4 W for LR4. These are module specifications, not blanket environmental approvals for a complete site or cabinet. In a warm equipment room, review the switch’s own permitted ambient range, fan operation, mounting position and the temperature measured around the installed equipment. A module designed to fit a QSFP28 cage still relies on the host platform’s thermal and electrical limits. Keep airflow paths clear and maintain normal rack cooling practices. If equipment is installed in an outdoor enclosure or unusually hot room, confirm the complete assembly’s environmental suitability rather than citing the optical module’s maximum figure in isolation. Do not assume weatherproofing or outdoor suitability.

Understand what the module does not include

An optical transceiver does not automatically supply a complete ready-to-use fibre circuit. Ubiquiti’s product descriptions state that fibre cable is not included with these 100G optical modules. Your project may separately require patch leads, permanent cabling, patch-panel components, dust protection, labelling materials, specialist cleaning equipment and commissioning tests. The exact list depends on whether the route is a new build or a reuse of existing infrastructure. Ask for a bill of materials that clearly separates the optical modules from required cabling and installation work. Avoid assuming that an advertised 100G module price includes fitting, testing, configuration or the far-end module. Where a link needs two transceivers, confirm quantities and endpoint assignments in the quote. This approach makes proposals comparable and avoids surprise accessory requirements after purchase.

Optical power and route loss matter

The published reach of an optic is useful for first-stage selection, but design acceptance should also consider optical loss across the complete channel. Loss can arise at connectors, splices, bends and damaged or contaminated sections. A route that is shorter than a nominal maximum distance may still fail if its physical condition is poor. Conversely, exceeding the manufacturer-stated reach should not be justified by an assumption that an unusually clean path will compensate. Have a qualified technician check the appropriate parameters against manufacturer documentation and the installed fibre. Keep measurement records so a future decline can be distinguished from an original installation defect. Do not confuse the module’s maximum electrical power consumption with optical transmit power or received optical signal level; they are different concepts. Where precise optical budgets are required for the design, use the exact model’s validated technical information and the route test data.

Build a useful bill of materials

A strong request for quotation identifies every element needed to commission the intended circuit. Start with the exact QSFP28 module model for endpoint A and endpoint B, the quantity at each end and the supported switch ports. Add the cable medium, approximate measured route length, connector presentation, patch-lead quantities, any necessary structured-cabling components and a note about testing. Include the rack or location labels used by the operations team, but exclude passwords or sensitive configuration data from ordinary quotation correspondence. State whether the request covers hardware only or also design, installation or commissioning, and confirm which services are actually available before making commitments. Ask the supplier to note any assumptions and exclusions. A sufficiently detailed bill of materials makes cost comparisons fairer and creates a traceable record for installation and future support.

What to tell FourTeck Tanzania

When asking FourTeck Tanzania about a Ubiquiti QSFP28 Module, provide the exact source and destination device models, the port speeds, the intended link distance and the fibre type. If the route is existing, state whether it is OM3, OM4, OS1 or OS2 and describe the available connectors. If the connector type is uncertain, say so rather than guessing. State the preferred Ubiquiti identifier if known, or request a technical selection based on those facts. Mention if you need one link, multiple redundant links or spare modules for maintenance. Share an approximate project timeframe only as planning context; do not assume delivery by a particular date. A good request asks for a clearly identified module, compatible patching requirements, current price, stock confirmation and any documented limitations. These details help avoid proposing the wrong optical technology based on a broad family name.

Validate cross-vendor connections carefully

Ubiquiti manufactures the optic family covered here, but some networks connect a UniFi switch to equipment supplied by a different vendor. That situation calls for extra compatibility review rather than an automatic assumption that any standards-labelled 100G optic will work. Check how the remote platform treats the transceiver, whether it supports the same physical Ethernet application and whether its vendor has compatibility guidance or a required module policy. Select a matching optical technology at the far end and agree on who will test the completed link. If a third-party module is proposed for either side, record the compatibility uncertainty and the fallback plan. A circuit that works in one firmware or hardware combination does not necessarily provide evidence for every possible revision. Where downtime has material consequences, test the exact device and optic combination before the production cutover.

Confirm operating modes, including 40G questions

Ubiquiti lists both 40 and 100 Gbps as supported data rates for the SR4 optic, while the PSM4 and LR4 pages cited for this guide list 100 Gbps. This is a model-specific distinction. It does not mean that every QSFP28 port can negotiate any rate, nor that the optics can be mixed without considering the remote port. Some switch specifications identify 100G/40G QSFP28 port modes, but the supported operating mode must still be checked for that specific host. If an upgrade is intended to begin at 40G before moving to 100G, document the planned phases and ask for explicit compatibility confirmation. If the design requires breakout arrangements or other special cabling, verify the switch’s own port support and the relevant accessory specification instead of inferring these capabilities from the transceiver’s headline data rate.

Clean and protect optical connectors

The quality of a fibre connection depends in part on the condition of its end faces. Keep dust caps fitted when the optical modules and patch leads are not connected. Use appropriate fibre inspection and cleaning methods, and follow equipment safety procedures rather than wiping the connector with ordinary cloth or exposing it to contamination during rack work. Ubiquiti’s care guidance recommends protecting unused ports and optics, cleaning modules before connection and handling them carefully. Schedule inspection before declaring a newly purchased optic defective; simple patching faults can look like transceiver problems. Maintain a labelled storage arrangement for spare modules and unused jumpers, particularly where several connector types and polish styles are present. Never look directly into an energised optical interface or fibre end. The optical modules are laser products and require the manufacturer’s safety precautions during handling.

Commission the link with a repeatable checklist

Before inserting the module, confirm the change window, identify both devices and take a record of the current network state. Verify transceiver labels and connector types against the approved design. Inspect and clean connector end faces using suitable tools, check patching and polarity, and seat the modules according to the equipment instructions. Then connect the intended fibre path and inspect link indicators and device status. Confirm the negotiated speed, endpoint identity and the expected forwarding behavior. Exercise representative traffic without confusing a single file-transfer result with the port’s nominal line rate. If the link is critical, record baseline monitoring values and agreed failover behavior. Save commissioning results, software versions and the final route labels with the network documentation. If the link does not come up, use a methodical diagnostic process rather than swapping several components at once and losing track of the cause.

Troubleshoot a link that stays down

Start with the basics: is each module fitted into a supported port, is the port administratively enabled and is the optic recognised by its host? Confirm that both modules use compatible optical technology and that the selected cable medium, connector and polish are correct. Next inspect patching, MPO polarity where relevant, LC fibre orientation, contamination and fibre damage. Check host port speed settings and any alerts in the management interface. If test equipment is available, compare measured optical conditions with the exact model’s requirements. Change one variable at a time and record the outcome so useful evidence is not lost. A fibre issue can resemble a module failure, just as a disabled port can resemble a patching problem. Escalate with the specific module labels, switch models, software revisions, link route and test observations rather than simply reporting that a 100G connection does not work.

Recognise a link with errors or unstable performance

A link that occasionally comes up but then reports errors needs a different investigation from a consistently dark port. Look at switch logs, interface counters, transceiver diagnostics if supported by the host, and the pattern of failures under load. Check for marginal fibre loss, contamination, poor patching, unsupported modules, excessive temperatures and configuration mismatch. Compare the same observations at both ends. Before replacing expensive equipment, establish whether the symptoms follow the module, the port, the patch lead or the physical route during controlled testing. Avoid claiming that a particular error counter definitively proves an optic fault without supporting evidence. Record when the issue occurs and whether the optical path has recently been altered. The result should be a documented corrective action and a verification test, not simply a temporary restoration of the link light.

Plan the maintenance and handover

A finished fibre connection needs an owner and useful records. Provide the IT team with the complete model identifiers, endpoint switch ports, port configuration, route and patch-panel references, connector types, approximate length and commissioning results. Document where any spare transceiver is stored and who may approve replacement. Include routine inspection responsibilities, alert thresholds appropriate to the network design and any scheduled testing of redundant paths. For a multi-site organisation, clear labels and records reduce dependence on the original installer. Where a network is expanded later, this documentation helps distinguish a compatible optical extension from a completely different connection type. Handover should also identify what was excluded from the original supply or installation scope. Good documentation does not add nominal bandwidth, but it protects the value of the equipment investment and improves service restoration when something changes.

Questions to resolve before procurement approval

Ask whether the planned circuit is new or replacing an existing uplink, which traffic is expected to use it, and how long it must remain operational without a maintenance interruption. Confirm that the budget covers both ends of the link, the correct fibre and patching, and any testing or installation work. Decide whether a spare is appropriate for the criticality of the route. Obtain written confirmation of the chosen Ubiquiti model and ask that any substitution be approved only after technical review. If the project involves a handover between teams, identify who is accountable for the switches, optics and passive fibre components. Keep price, stock, warranty terms, expected delivery and service scope as quotation-specific items that require confirmation rather than as assumptions embedded in product descriptions. This last review is where technical fit and commercial clarity come together.

When a different connection type may be more appropriate

Not every network needs a 100G optical module. If the equipment lacks a QSFP28 port, if the expected traffic is much lower, or if the site already has a suitable lower-speed uplink, another supported interface may be a more proportional choice. For certain very short connections, equipment vendors may offer direct-attach cable solutions, but these are distinct products with their own lengths and compatibility requirements. A 25G SFP28 or 10G SFP+ link might be appropriate when the application and hardware call for it; those are not interchangeable with a 100G QSFP28 optic. Evaluate total installed cost, growth expectations, management complexity and the disruption needed to replace a working path. The correct purchasing outcome is a network connection that meets an agreed requirement, not necessarily the highest advertised speed on an accessory label.

Planning examples for Tanzania-based organisations

Consider three hypothetical requirements rather than assuming that one module is appropriate everywhere. An equipment room with an existing short OM4 MPO path could investigate SR4 after verifying length and port support. A campus path with identified OS2 single-mode cabling and an MPO APC design could investigate PSM4 for a run within its documented reach. A longer route using a suitable duplex LC single-mode path could investigate LR4, provided the full channel is within its supported characteristics. These examples describe technical selection methods, not real installations, local stock or guaranteed compatibility. In every case the site team should confirm fibre records, endpoint hardware, commissioning scope and maintenance ownership. Local operating conditions, power continuity and cabling protection may also influence the network design, but they do not change the manufacturer’s optical specifications. Evaluate the real circuit rather than buying by example alone.

Make comparisons meaningful during quotation review

If several suppliers propose a 100G connection, compare the technical line items before comparing their totals. Look for exact model names, quantity of transceivers, correct connector and fibre specification, cable lengths, termination approach, and any testing included. Ask whether the proposed solution assumes an existing working fibre path or includes work to establish one. For a PSM4 proposal, verify that the OS1 or OS2 distinction has been handled correctly; for SR4, confirm OM3 or OM4 and the appropriate reach; for LR4, confirm the duplex LC single-mode arrangement. Check the declared exclusions and the responsibility for support if the optics and switches come from different parties. Request clarification on unsupported alternatives rather than accepting the same generic description at a different price. A technically comparable quote is much easier to approve and administer.

Preparing for later network expansion

The initial uplink may be only the first part of a larger 100G rollout. During design, identify spare switch ports, unused fibres, patch-panel capacity, rack space, cable-management routes and the availability of documented spares. Consider whether future connections will use the same fibre type and connector format or cross different distances requiring different optics. Do not standardise on a single transceiver model across unrelated routes without considering their physical requirements. Maintain a model-to-location register so that additional modules can be requested accurately. If 100G is being introduced as an aggregation layer, review the expected growth in access links and downstream device capability. Planning ahead improves the accuracy of the first order while allowing later changes to proceed without repeatedly rediscovering the installed fibre plant.

Frequently asked questions about 100G QSFP28 modules

Is the Ubiquiti QSFP28 Module one specific model?

No. The broad product phrase describes a family, and this guide covers three documented 100G optical models: SR4, PSM4 and LR4. Each has a different fibre and connector requirement. The correct item should be identified by its complete manufacturer model code before ordering. If your quotation names only QSFP28, request confirmation of the exact optic and its suitability for the route.

Which Ubiquiti QSFP28 option is suitable for OM4 fibre?

Ubiquiti’s UACC-OM-QSFP28-SR4 is the listed multimode option with a maximum documented reach of 100 metres on OM4 fibre. It requires the specified MPO-12 Type B UPC connection and a compatible port and far-end optic. Confirm the installed fibre type, pathway and polarity first. Do not assume that any available OM4 patch lead has the correct connector or end-to-end mapping.

What changes when the fibre is OM3?

The same SR4 model has a shorter manufacturer-listed reach on OM3: 70 metres, compared with 100 metres on OM4. Measure the complete installed route, including patching, rather than using the approximate distance between network racks. If the route exceeds the documented limit, reassess the optical and cabling design instead of assuming that a higher-cost module will solve the issue without other changes.

Can PSM4 operate over OS1 single-mode fibre?

Ubiquiti’s PSM4 product information specifies up to 2 km over OS2, but limits transmission to 500 metres over OS1. Verify which cable is installed before selecting the module. The model also uses MPO-12 Type B APC, so the connector and fibre mapping must be checked. Do not apply the OS2 distance to an unidentified single-mode route.

Which option uses a duplex LC connector?

The UACC-OM-QSFP28-LR4 uses duplex LC UPC with single-mode fibre and is specified for 100 Gbps links up to 10 km under appropriate conditions. SR4 and PSM4 instead use MPO interfaces. If an existing path terminates in LC connectors, inspect its fibre type, polish, route and endpoints rather than selecting LR4 solely by connector appearance.

Can I insert a QSFP28 module into an SFP28 port?

No. QSFP28 and SFP28 are distinct physical interface families and should not be treated as interchangeable. Check the hardware’s exact port type and supported link rates before purchase. A switch with 25G SFP28 uplinks does not automatically have a 100G QSFP28 optical interface. The correct optical accessory follows the supported port configuration, not only the target bandwidth.

Do I need a module at each end?

A normal point-to-point fibre connection requires compatible active interfaces at both endpoints, but the right transceiver and patching on each side depend on the devices and design. Include both endpoints in the bill of materials and record any module already installed at the far end. Do not assume that the purchase of one transceiver includes another unit, a patch cable or installation.

Can SR4 and LR4 communicate directly?

They are different optical technologies with different connector formats and fibre requirements. SR4 is a multimode MPO solution, while LR4 is a duplex LC single-mode solution. Do not treat them as a matching 100G optical pair. Select a coherent end-to-end design using the approved equipment, cabling and compatible modules at both ends.

Does a 10 km rating guarantee success on a 10 km route?

No. The LR4 module’s stated 10 km reach is an upper published distance, not a blanket guarantee for every physical link. Real installations include splices, connectors and other sources of loss. Confirm the total channel length, the condition and type of fibre, the far-end optic and the link’s measured characteristics before commissioning.

What is the difference between UPC and APC?

UPC and APC are different optical connector end-face finishes. This matters here because the SR4 uses MPO UPC while PSM4 uses MPO APC; LR4 uses duplex LC UPC. Do not intermingle connector types on the assumption that similar-looking plugs are interchangeable. Use the specified cable and patching arrangements for the chosen model.

Is a 100G QSFP28 connection the same as 100G internet service?

No. An optical module provides a network interface with an advertised link rate. Internet service speed, application throughput and end-to-end data-transfer results are determined by many other factors, including upstream connections, host capability and traffic overhead. Buy a 100G optical link for a demonstrated network requirement rather than assuming it upgrades an internet subscription or server automatically.

Can a 100G optic be used with a 40G port?

The answer is model-specific and host-specific. Ubiquiti lists 40 and 100 Gbps rates for its SR4 module, and certain switch specifications list 100G/40G QSFP28 port modes. That does not guarantee compatibility in every 40G port or with every far-end optic. Verify the precise device, software and physical optical application first.

Is fibre cable supplied with the Ubiquiti module?

Ubiquiti states that fibre cable is not included with these optical transceivers. The project may also need patch leads, termination hardware, cleaning materials, test work and a compatible transceiver at the far endpoint. Ask for those elements to be itemised in the quotation so the total installed requirement is understood before approval.

How can I request a quotation in Tanzania?

Provide FourTeck Tanzania with your preferred model if known, both endpoint switch models, port type, measured route length, fibre designation and connector details. Also state the number of links, whether any cabling already exists and whether you need a hardware-only quotation or an explicitly confirmed service scope. Request confirmation of the exact module, current price, stock, terms and any additional cabling requirements. No local price, availability or lead time is assumed in this guide.

Request the correct Ubiquiti 100G QSFP28 module

Send FourTeck Tanzania the two switch model numbers, your fibre type, connector details and measured link distance. State whether you need SR4, PSM4 or LR4 if already confirmed; otherwise ask for the exact model to be identified against your requirements. Request a quotation that clearly itemises the module, matching cable accessories and any separately confirmed services. Product availability, local pricing, warranty terms and delivery arrangements should be confirmed for the exact proposed item before you place an order.

Next step: Contact FourTeck Tanzania with your network requirements for a model-specific quote.