Ubiquiti UniFi Pro 48 PoE (USW-Pro-48-POE)
Connect and power compatible Wi-Fi access points, IP cameras and office devices using a managed 1U switch with forty PoE+ ports, eight PoE++ ports, four separate 1/10G SFP+ uplinks and a shared 600W PoE budget. The Ubiquiti USW-Pro-48-POE is a practical candidate when your organisation needs an organised Gigabit access layer, central UniFi management and defined Layer 3 features.
For Tanzania procurement, prepare your device and power schedule before requesting a quote. Exact local price, stock, accessories, delivery and support terms need to be confirmed for the proposed order.
Specifications at a glance
Choosing the Ubiquiti USW-Pro-48-POE for a growing network
The Ubiquiti UniFi Pro 48 PoE is designed for networks with many wired endpoints and several devices requiring power over Ethernet. It offers forty-eight Gigabit RJ45 access ports, a large shared PoE allocation, and separate high-speed SFP+ uplinks in one rackmount chassis. This combination can suit an office, educational facility, hospitality property or surveillance installation that wants a controlled access layer instead of numerous independent unmanaged switches. The model is a switching component, however, rather than a complete internet connection or security appliance.
Before choosing the hardware, count the physical Ethernet connections needed now and after a realistic expansion period. Separate ordinary data devices from access points, cameras, phones and other equipment receiving PoE. Record where each device is installed and whether its manufacturer specifies PoE, PoE+ or PoE++. A project that has forty-eight cables but only ten powered endpoints has different requirements from one with forty-eight cameras. An accurate endpoint inventory is more useful than assuming the largest available switch is automatically the right purchase.
A buyer should also identify the upstream topology. The four 1/10G SFP+ ports can support compatible uplinks, but a cable, optical module and appropriately rated device at the other end are still required. Management is provided through the UniFi Network environment, so an existing management arrangement or a suitable console/application is another part of the design. Request a quote based on the complete device schedule instead of selecting this model solely from the port count.
What the 48 Gigabit ports can and cannot do
The forty-eight copper interfaces support 10/100/1000Mbps Ethernet connections. Forty ports supply standards-based PoE and PoE+, while eight additional ports can supply PoE++ as well. They are all Gigabit data ports; PoE++ describes their electrical power capabilities and does not increase Ethernet speed. A switch with forty-eight Gigabit ports is useful when many individual endpoints each require a standard wired connection, even if their traffic is aggregated over faster backbone links.
Some modern Wi-Fi access points and workstations support 2.5GbE or faster. Those devices will not gain a 2.5Gbps copper connection from this model because its RJ45 access interfaces top out at Gigabit. The device may negotiate a lower rate if both sides support it, but the buyer must confirm compatibility and expected performance. If the project explicitly requires numerous multigigabit access connections, compare switches that provide those interfaces rather than relying on a Pro designation.
Assign every planned endpoint to a proposed port group and keep a record of unused capacity. Reserve the eight PoE++ ports for equipment whose verified requirements justify them. Port capacity should include future growth, replacement devices and occasional troubleshooting connections. A clear patch-panel schedule also makes support easier: a technician should be able to identify where a camera, phone or access point is connected without disconnecting several unidentified cables.
The 600W shared PoE budget explained
The published 600W figure is a shared budget across all powered Ethernet connections, not an amount available to each one. The switch’s individual port limits and an endpoint’s negotiated PoE standard also apply. Ubiquiti’s current specifications describe forty PoE+ ports, eight PoE++ ports and up to 60W per PoE++ port by the power-sourcing equipment. A project that requires every port to operate near its maximum power class cannot assume that this shared budget will accommodate the complete load.
A reliable design starts with the maximum expected power of each camera, access point, telephone and controller. Add the device requirements and compare the aggregate with 600W, leaving headroom for changes and operating variations. As a simple illustration, devices requiring 375W in total would leave 225W of the published budget unused, but the example does not establish compatibility: an individual device could still exceed its assigned port’s capability. The maximum draw values should come from the exact connected models.
Do not use an idle reading as the only basis for capacity planning. Some cameras use more energy when night illumination is enabled, while wireless access points or accessories can have changing power demands. A power plan should consider startup behaviour and future additions as well as normal operation. If the predicted load is close to the shared budget, consider redistributing devices or choosing a different power design. This is especially important for installations where failure of a powered endpoint would affect safety or business operations.
Matching PoE, PoE+ and PoE++ endpoints
PoE makes it possible to carry electrical power and Ethernet data on a suitable cable, simplifying the placement of compatible equipment. Standard IP phones, fixed cameras and many wireless access points may use PoE or PoE+; higher-demand devices can require PoE++. These labels are not interchangeable with passive or proprietary power methods. Verify the exact IEEE standard and required input arrangement for each endpoint before connecting it to a powered switch port.
The eight PoE++ ports are important for devices that cannot operate correctly within a PoE+ supply limit. These may include some high-performance access points, PTZ cameras and specialised control products, but compatibility must be assessed per model. A device may establish a data link yet operate with disabled features when insufficient power is negotiated. Test the required device functions under representative conditions, rather than taking the presence of a link light as proof that the power design is adequate.
Cable properties and installation quality also affect reliable PoE operation. Long or poorly terminated copper links can create voltage drop or intermittent connectivity. Use appropriate cabling for the intended application, document run lengths and consider cable bundles where many higher-power devices are installed. For outdoor or exposed links, apply the equipment manufacturer’s protection and grounding guidance. The switch itself should remain in a suitable protected environment rather than being treated as outdoor-rated equipment.
Four separate 1/10G SFP+ uplinks
Beyond the forty-eight copper ports, the switch supplies four SFP+ interfaces that support 1G and 10G networking with suitable modules or direct-attach links. These connections can be used to connect an access rack to a distribution switch, core network or another compatible higher-speed device. A separate optical uplink helps preserve copper access ports for user devices. It can also support the aggregation of traffic from many Gigabit endpoints, subject to the complete network topology.
An SFP+ slot is not a complete fiber connection by itself. The installer must select compatible optics or supported direct-attach cabling, matching the operating speed and the physical medium at both ends. For fiber, verify whether the route uses single-mode or multimode cable, suitable connectors, transceiver type and an acceptable link distance. A module that fits into a socket may still fail to establish a link when the speed, optical parameters or neighbouring equipment do not match.
Ten Gigabit is an uplink capability, not the speed guaranteed to every network user. A single copper endpoint remains limited by its negotiated Gigabit connection, and traffic may be constrained by storage, the gateway, downstream equipment or a shared upstream path. Design the uplinks from expected traffic flows and document any planned aggregation or resilience configuration. Plugging in additional parallel cables without the correct switching configuration can create an avoidable network loop.
Understanding switching capacity and throughput
Ubiquiti publishes 176Gbps switching capacity, 88Gbps total non-blocking throughput and a forwarding rate close to 131 million packets per second for this switch. These values help describe the device’s internal packet-forwarding capability. They should not be confused with internet speed or the transfer speed a single workstation can achieve. The actual user experience depends on the source and destination ports, protocol overhead, traffic patterns and any shared uplink or gateway.
Consider two very different deployments. A group of office computers accessing a local server may send much of its traffic across one part of the wired LAN, while cameras recording to a remote server may concentrate several video streams on an uplink. In each case, the important design question is where traffic converges. A nominally fast switching fabric cannot compensate for an under-sized server interface, congested wireless medium or internet service with limited capacity.
A procurement comparison should therefore look beyond the largest throughput figure. Count the number of copper links, the class and number of powered ports, the usable PoE budget, uplink speed and the management features actually needed. Confirm how packets will travel between network zones. These practical considerations generally provide more value than a theoretical benchmark divorced from the intended topology.
Managed VLANs and network separation
The managed Layer 2 feature set makes it possible to organise different types of connected devices into separate VLANs. A business might distinguish staff equipment, visitor Wi-Fi, surveillance systems, voice devices and network administration. VLAN separation can reduce unnecessary broadcast exposure and make network operation easier to understand. It does not by itself create a comprehensive firewall or guarantee that one network is unable to reach another.
For every VLAN, document its purpose, subnet, DHCP arrangement, permitted destinations and access policy. Then configure the corresponding access ports and tagged uplinks consistently throughout the switching path. A misconfigured trunk may cause one wireless network to stop working or place an endpoint onto an unintended segment. Include the gateway and wireless equipment in testing, because those systems help determine how VLAN tagging and routing behave end to end.
The USW-Pro-48-POE supports a range of managed controls that Ubiquiti identifies in its current specifications, including link aggregation, spanning tree, port isolation, monitoring features and access controls. Select these according to the network design instead of enabling everything indiscriminately. Operational teams should retain an approved configuration record and know how to restore management access after a mistaken network policy change.
Layer 3 routing and its boundaries
The model provides Layer 3 capabilities for selected local network functions. Current Ubiquiti documentation includes local inter-VLAN routing, static routing, DHCP server operation for local networks and DHCP relay. This can allow certain local subnets to exchange traffic through a Layer 3 switch instead of requiring all such traffic to pass through an upstream gateway. The decision is architectural: routing convenience must be balanced against the location of security controls and traffic inspection.
A Layer 3 switch does not automatically replace a router, firewall or complete internet gateway. Ubiquiti’s Layer 3 guidance describes working with either a compatible UniFi gateway or a properly configured third-party gateway. The third-party option depends on VLAN support and manual static routing. The switch does not perform network address translation in that design, and gateway-based traffic-identification features may not apply to networks routed locally by the switch.
Before adopting switch-based routing, specify every network and permitted flow, how DHCP is assigned, which device provides the default route and where access rules are enforced. Verify software capabilities on the installed UniFi Network and firmware versions. For businesses with advanced security or application inspection requirements, retain a suitably designed gateway solution alongside the switching layer. Treat Layer 3 support as a set of defined functions, not a blanket promise that all enterprise routing features are present.
Managing the switch through UniFi Network
UniFi Network gives administrators a way to adopt and centrally manage compatible Ubiquiti devices. For the Pro 48 PoE, this can include port configuration, network assignment, operational status and troubleshooting information. Such visibility is helpful at sites with several switches and wireless access points because staff can use a consistent approach to network naming, planned changes and device monitoring. The management experience depends on a suitable UniFi console or application being available and properly maintained.
An installation plan should identify the intended management host, software compatibility, administrative accounts and management VLAN. If that application sits on another subnet, account for the network path and required adoption traffic before the switch is installed in a remote rack. Label physical ports to match the software descriptions and make the mapping accessible to authorised personnel. Otherwise a detailed management dashboard cannot tell a technician which unlabelled ceiling cable to repair.
Routine management includes reviewing link errors, PoE demand, unexpected port changes and appropriate software updates. Protect the management interface with strong credentials, sensible permissions and a documented configuration recovery procedure. Schedule important updates during approved maintenance windows and confirm critical functions afterwards. The operational benefit of central management is greatest when configuration records and network diagrams remain current.
Business Wi-Fi deployments
PoE switching is a useful foundation for an organised Wi-Fi network, but it is not a substitute for access point planning. Wireless performance depends on building materials, radio interference, device density, access point placement and upstream capacity. The Pro 48 PoE can power many compatible access points and connect them to a managed network. Each connected RJ45 access point still receives at most a Gigabit copper link from this switch, even when the access point itself supports faster Ethernet.
Begin with a wireless coverage and capacity assessment, then translate the result into endpoint count, port allocation and power requirements. Some access points require PoE+, while others need PoE++ for full operation. Assign the appropriate ports and verify supported device modes. Where multiple SSIDs serve staff and visitors, plan corresponding VLANs, gateway restrictions and the tagged network path. A correct access point configuration cannot compensate for a missing VLAN on the upstream switch.
Commission the wireless service at busy and quiet times where practical. Check client connectivity, roaming, service access, wired negotiation speed and PoE draw. If Wi-Fi is important to point-of-sale equipment, staff tablets or operations, consider upstream redundancy and backup power for all critical network devices. A high-power switch helps with access point supply, but it alone does not ensure continuous connectivity.
IP surveillance and camera networks
A managed PoE switch can bring a group of compatible IP cameras onto a clearly organised network without separate power adapters for every endpoint. Use the forty PoE+ ports for devices whose ratings fit that class and the eight PoE++ ports for supported higher-power cameras. Cameras with infrared lighting, movement motors, heaters or other accessories can have changing electrical requirements. Review maximum device power rather than selecting ports from camera appearance alone.
Network bandwidth should be sized according to the number of camera streams, resolution, frame rate, codec, recording path and concurrent viewing demand. Streams sent to a remote network video recorder may traverse an uplink shared with other services, while some traffic in a local design stays within the same network segment. The switch moves data; it does not itself provide recording storage or a surveillance platform licence. Include the NVR, storage and playback systems in the bill of materials.
Separate surveillance administration from public or visitor networks as appropriate, and set clear access permissions for viewing and configuration. Record each camera’s physical location, cable route, VLAN and assigned power class. Validate night-mode operation, recording continuity and link health during acceptance testing. Where cameras are mounted outside, include the required cable, protection and environmental details without placing the rack switch in an exposed enclosure.
VoIP telephone and voice networks
Standards-compliant PoE desk phones can receive power and data over one network cable, making a managed PoE switch a useful component of an office voice deployment. Ubiquiti lists voice-oriented functionality including voice VLAN and LLDP-MED for this model. Whether those features are used depends on the phones and call-platform requirements. Confirm the exact handset models, their power class and any necessary voice network settings before a cutover.
Voice service quality relies on the complete path between endpoints and the calling platform. Packet loss, latency variation, congestion and gateway configuration can reduce call quality even when every desk phone has an active Gigabit link. Set appropriate VLANs and quality-of-service policies where required, and test signalling as well as real calls. Check that the configured upstream path can carry simultaneous voice and other business traffic without unexpected contention.
If telephones support essential operational functions, include the gateway, switch, call platform and any related equipment in the continuity plan. A UPS should be sized for the full load and required runtime, not simply the switch’s idle consumption. Test phone registration and calling after a restart and confirm any failover behaviour. A correctly powered handset is only one part of a usable business telephone service.
Hotels and hospitality networks
Hospitality environments often have a mixture of guest wireless access, staff workstations, management systems, IP cameras, telephones and building services. The Pro 48 PoE may suit a distribution rack where many such endpoints need controlled wired access and power. Keep guest traffic separate from internal administration or payment systems according to the network policy. The relevant VLAN and firewall rules must be configured across the complete topology, not only on one switch.
Calculate endpoint requirements by building, wing or floor. Large properties may exceed copper cabling distances or have equipment concentrated in several communications rooms. In those circumstances, use appropriately located switches and plan fiber or other suitable uplinks instead of stretching copper runs beyond acceptable limits. The four SFP+ interfaces on this model support a range of planned uplink arrangements, provided compatible modules and remote equipment are selected.
During commissioning, check guest service, staff connectivity, camera recording and management access independently. Document the relationship between rooms, devices and switch ports. A busy property may need additional attention to uptime and maintenance windows, since interrupting one shared switch can affect several services at once. The best deployment is one where physical layout, power planning and network segmentation are considered together.
Schools, training centres and campus environments
Educational facilities can use a managed access switch to connect teaching computers, administrative devices, access points, phones and surveillance equipment. Separate academic, guest and administration traffic as required by policy, with a suitable gateway enforcing permitted communication. Device counts may change significantly between classrooms, laboratories and shared spaces. Build a port schedule from the actual room plan and keep capacity for future learning equipment.
The number of Ethernet connections is different from the number of powered endpoints. Desktop computers generally use their own power, while access points, phones or cameras may draw from the switch. A careful assessment avoids overestimating or underestimating the shared 600W budget. Some high-density wireless deployments also need multigigabit copper uplinks to access points; in that case, compare the Pro 48 PoE’s Gigabit access ports with other suitable models.
A campus with several buildings may require multiple racks and correctly designed fiber connections. Assess physical security, ventilation, power protection and maintenance access in each communications room. Keep a diagram of uplink paths and management networks, then test the services users actually need. The switch’s role is to provide an organised, manageable access layer inside that larger campus design.
Office consolidation and branch infrastructure
Growing offices often accumulate small switches and power injectors as new teams, cameras and wireless devices are added. A forty-eight-port managed switch can help consolidate an appropriately sized group of those connections in a structured cabinet. The advantage is not only fewer devices but clearer assignments, power accounting and network policy. It remains important to verify that the combined load and expected traffic fit the switch rather than treating consolidation as an objective at any cost.
For a branch, record which ports serve employees, uplinks, printers, access points, cameras and infrastructure devices. Configure the correct VLAN and permitted network paths, then label the physical patch panel to correspond with those assignments. If business systems depend on a central office or remote services, plan gateway connectivity and the effect of losing the branch uplink. A managed access switch cannot restore an internet service that is unavailable upstream.
Operational resilience improves when a site has a documented design and a clear recovery procedure. Preserve the intended switch settings, identify who may administer them and record the installed cable and module types. Expansion should trigger a review of free ports, PoE headroom and uplink utilisation. The hardware provides useful building blocks, while day-to-day support quality depends on how well the overall network is managed.
Rack dimensions, cooling and the environment
The Pro 48 PoE uses a 1U rackmount steel enclosure of approximately 442 × 400 × 44mm. Plan enough rack depth for the device, power and network connections, and cable management rather than considering front-panel height alone. The published operating temperature range is minus 5°C to 40°C, with 10–90% non-condensing humidity. These figures are equipment limits, not a guarantee that a sealed communications cabinet will remain within them.
A rack may contain a UPS, network recorder, router, patch panel and other equipment that generates heat. Assess the combined temperature and airflow requirements, particularly in a small room or enclosed cabinet. Ubiquiti describes near-silent cooling, but that description should not be interpreted as fanless operation or a fixed acoustic promise for every load. Select a protected indoor environment with appropriate ventilation and access for maintenance.
Physical installation should include safe mounting, power isolation arrangements, protective earthing and strain relief for cabling. Avoid locations exposed to water leaks, uncontrolled dust or accidental tampering. Plan cable entry and bend radii carefully, especially for optical modules and dense patch panels. Clearly labelled equipment can make fault diagnosis easier and reduce disruption when hardware is moved or replaced.
AC power and redundancy planning
Ubiquiti lists 100–240V AC, 50/60Hz input, a 660W internal power supply, and maximum power consumption of up to 60W without PoE output or up to 660W including PoE output. This is why a UPS or power distribution plan cannot be based on the shared 600W PoE budget alone. Electrical demand will vary with the installed devices, but the full system must be considered when sizing protective power equipment and cabinet cooling.
The switch has a DC backup input designed for use with a compatible USP-RPS redundant power system. That connection is a supported capability and does not establish that a redundant power unit is supplied with the switch. A separately specified UPS serves a different continuity role. Confirm exactly what is included in any quote and how the proposed redundant equipment would behave during a specific failure scenario.
For projects in Tanzania, check actual site power conditions, grounding and the desired outage runtime. Do not assume every building has the same distribution or protection arrangements. Include essential upstream devices, recorders and management equipment when calculating operational continuity. The strongest resilience plan specifies both how a system should survive a power disturbance and how that behaviour will be tested after installation.
Copper cabling and site protection
Correctly installed structured cabling is important for reliable Gigabit data links and standards-based PoE. Select suitable cable materials, lengths, connectors and installation routes based on the endpoint and project standards. Poorly terminated links can create intermittent speed negotiation, connection drops or reduced reliability of powered equipment. Label both cable ends and test installed links instead of assuming that a new cable run is automatically sound.
High-power Ethernet installations also benefit from attention to cable bundles, heat, routing and connector quality. Do not choose cable solely because its packaging says that it can connect to a network switch. For outdoor endpoints, use appropriate protection and grounding arrangements in line with manufacturer guidance and applicable installation practice. The switch should be housed in a suitable protected cabinet even when some of its network cables extend outdoors.
A detailed cable register should show the patch-panel number, switch port, device location, cable specification and any known environmental exposure. This information makes it easier to isolate faults and reduces accidental interruption of other services. A network designed around disciplined physical cabling will generally be easier to expand and support than one where cables are added without consistent documentation.
Fiber modules and direct-attach cabling
The SFP+ slots are useful only when the media and remote interfaces are correctly matched. For a fiber link, specify the intended speed, distance, fiber type, connectors and transceiver characteristics at each end. For a supported short direct-attach connection, confirm cable compatibility and length. Neither a visible SFP+ socket nor a module that fits mechanically is proof that the final connection will function.
An installer should check the route for safe fiber bend radius and appropriate termination. Where an optical link is designed between buildings, consider the site-specific protection, route length and management arrangement. Test the finished optical path and confirm negotiated speed before turning it over for production use. A physically connected uplink can still suffer errors or remain at an unexpected rate if the components are not matched properly.
For a quote, distinguish the base switch from optics, fiber patch cords, direct-attach cables and external equipment. These components may form a material part of the network design and should not be assumed included. Ask for exact compatible accessories once the intended topology is known, and keep the as-built module details in the support documentation for future replacements.
Network security and access controls
A managed switch makes more granular network access design possible, but it does not secure a business automatically. Start with an explicit policy for employees, guests, security cameras, phones and infrastructure administration. Configure VLANs, route permissions and gateway firewall rules to follow that policy. Some local traffic may be routed on the switch while other traffic passes through an upstream gateway, so the place where inspection or blocking occurs must be understood.
Current manufacturer specifications list controls such as 802.1X, DHCP snooping, port isolation, ACLs and traffic-related safeguards. Use the controls that suit the deployment and verify operation under the installed software environment. A guest VLAN name is not a complete barrier, and a device plugged into an incorrectly configured trunk can create unexpected access. Validate allowed and blocked communication after every important configuration change.
Protect the UniFi management environment with appropriate identities, restricted access and an update process. Maintain a change log and retain a method of restoring access if a network setting is misapplied. Monitor unusual port activity and investigate unexplained power changes or recurring connection failures. A consistent security operating procedure is more useful than enabling a long list of settings without a defined purpose.
Replacing an old managed switch
A migration begins with a record of the existing environment: port assignments, VLANs, trunks, aggregated links, management addresses and power requirements. Photograph or document the patch layout and prepare a mapping from each old port to its intended new position. Check for existing proprietary or passive PoE arrangements that cannot simply be transferred to a standards-based PoE port. The presence of an RJ45 connector does not prove equivalent electrical behaviour.
Before the maintenance window, configure the target management system, check uplink optics and confirm cabinet depth and available power. Prepare a rollback path if the new configuration fails. During the cutover, reconnect critical services in a planned order and check actual business functions, not only port status. Parallel uplinks should be added only under a correctly designed aggregation or spanning-tree configuration.
After migration, validate access point adoption, user network access, camera recording, phone calls, routing and policy isolation. Observe PoE demand and link quality under ordinary workload. Update the port register and provide a handover summary to authorised support personnel. A successful replacement is one that restores expected services while leaving behind a clearer and maintainable network configuration.
Deployment acceptance testing
Commissioning should confirm the exact hardware model, physical mounting, power arrangement, management adoption and software state. Configure the intended network groups and make sure the administrator can reach the switch over its approved management path. Record the installed firmware and relevant controller version. Confirm that an unexpected failure or power restart does not leave critical infrastructure in an undocumented state.
Test representative PoE+ and PoE++ endpoints on the correct port classes and verify their actual application behaviour. Compare the combined device power demand with the shared 600W budget. Test 1G and 10G uplinks where specified, using the actual modules and cable routes. Check negotiated link speed, path redundancy if configured, and whether any important traffic is unexpectedly concentrated on a slower connection.
User-facing acceptance tests should include wireless SSIDs, intended VLAN access, camera recording, phone registration, business services and prohibited cross-network access. Where backup power is part of the design, perform an agreed and safely controlled continuity test. Keep a record of open issues before final handover. This helps distinguish a healthy production installation from one that merely looks complete because the switch powers on.
How to compare this model with alternatives
The USW-Pro-48-POE is a compelling candidate when a site truly needs numerous Gigabit access connections, eight higher-power PoE++ sockets, a 600W shared power budget and four SFP+ uplinks. A smaller switch may be more proportionate for a compact site. A model with less PoE capacity may also meet a network where most ports serve self-powered computers. Conversely, a surveillance-heavy installation can exceed the available PoE budget despite having enough physical connectors.
Buyers planning high-throughput wireless access points or workstations should check copper port speeds carefully. If a large portion of endpoints requires 2.5GbE, 5GbE or 10GbE at the access port, this Gigabit switch may not be the best fit. Other designs may require additional optical uplinks, higher-density PoE++ or specialist switching functions. Evaluate current exact models, not a family name or a price comparison stripped of the requirements.
Compare total deployed cost: switch, optics, copper patching, fiber installation, UPS capacity, gateway, rack and management overhead. Also consider service impact during upgrades and the skills of the people maintaining the network. Choosing the device that matches the real topology often delivers better long-term value than purchasing one solely for a high quoted bandwidth or power figure.
Requesting a Tanzania quotation
For a meaningful quotation from FourTeck Tanzania, identify the required quantity and the exact model USW-Pro-48-POE. Provide a schedule of connected devices, including the number of ordinary data endpoints, PoE+ devices and PoE++ devices. Include maximum endpoint wattages where available and describe the intended uplinks, required media and distance. A simple network sketch can help when the installation covers more than one rack or building.
Ask what equipment and accessories are included in the proposed offer. Optical modules, direct-attach cables, a redundant-power unit, UPS equipment, cabling and installation work should be separately identified if needed. The manufacturer’s model number is not a verified SKU for the Tanzania listing; no user-supplied listing SKU is available here. Do not rely on prices or product availability observed in unrelated international markets as evidence of a local quote.
Before committing to the order, confirm local selling price, the exact product package, stock or lead time, delivery arrangement and applicable support or warranty terms directly. No such commercial claims are made in this description. For an important network, request a compatibility check against the final endpoint inventory so that port count, per-device power, aggregate load and uplink requirements are considered together.
Technical specification table
| Exact model | USW-Pro-48-POE |
|---|---|
| Brand | Ubiquiti |
| Copper Ethernet ports | 48 × 10/100/1000Mbps RJ45 |
| PoE class distribution | 40 × PoE+ and 8 × PoE++ |
| SFP+ ports | 4 × 1/10G |
| Shared PoE budget | 600W |
| Current PoE+ PSE per-port maximum | 32W |
| Current PoE++ PSE per-port maximum | 60W |
| Switching capacity | 176Gbps |
| Total non-blocking throughput | 88Gbps |
| Forwarding rate | Approximately 131Mpps |
| Layer 3 functions | Local inter-VLAN routing, static routing, DHCP server and relay |
| Form factor | 1U rackmount |
| Dimensions | Approximately 442 × 400 × 44mm |
| AC input | 100–240V AC, 50/60Hz |
| Internal power supply | 660W |
| Maximum draw | 60W excluding PoE, 660W including PoE |
| Backup-power input | Compatible USP-RPS DC input |
| Display | 1.3-inch front touchscreen |
| Operating temperature | −5°C to 40°C |
| Operating humidity | 10–90% non-condensing |
| Management | UniFi Network |
Technical specifications are manufacturer-derived. Software-dependent capabilities and accessory compatibility should be checked at implementation. Commercial terms are not inferred from international sellers.
Frequently asked questions
How many ports have PoE?
All forty-eight RJ45 access ports support standards-based PoE, but the power classes differ. Forty provide PoE/PoE+ and eight support PoE++ in addition. The higher-power ports are particularly relevant to supported endpoints needing the 60W PoE++ class. The same shared 600W budget applies across them, so a plan should list each connected device’s maximum draw and assigned port before deciding that the switch is sufficient.
Can every port draw its full maximum power at once?
No. The total power budget is 600W, shared among all powered ports. Individual PoE and PoE++ port limits also apply. Even if the total power calculation looks acceptable, a particular endpoint may not be compatible with the allocated port. Use exact device specifications, allow for realistic power changes and check the combined load rather than treating each port specification as an independent unlimited supply.
Are the four SFP+ ports extra ports?
Yes. There are forty-eight Gigabit RJ45 connections plus four separate 1/10G SFP+ interfaces. The SFP+ interfaces are typically used for suitable high-speed uplinks or other compatible connections. Their operating rate depends on installed media and the hardware at both ends. They do not make the copper access connections faster than 1Gbps, and modules or direct-attach cables should be specified separately for a complete link.
Does it support 2.5Gbps copper access points?
Its copper RJ45 interfaces provide up to Gigabit Ethernet, not 2.5GbE. A faster-capable access point may negotiate a lower compatible speed, but that must be verified for the specific device. PoE power must also be checked independently. If a network requires faster-than-Gigabit copper links to many endpoints, compare products that explicitly include multigigabit access ports rather than assuming the Pro 48 PoE meets that requirement.
Can it route between VLANs?
The switch supports selected Layer 3 functions including local inter-VLAN routing, static routing, DHCP server functions and DHCP relay. Deployment requirements are described in Ubiquiti’s current guidance and may involve a compatible UniFi or third-party gateway. The switch does not provide all the functions of an internet router or security firewall. Confirm where filtering, default routing and management features will operate in the finished design.
Is a gateway or firewall still required?
A suitable upstream gateway is normally needed for internet connectivity and gateway-specific security or network translation functions. The switch provides managed switching and some local routing features but is not a universal substitute for those systems. A third-party gateway may be used in supported designs when its VLAN and static route settings are properly configured. Assess the required security policies and external network connections before defining the final topology.
Will it run cameras and telephones?
It can supply many standards-compliant cameras, access points and IP telephones when their data and power requirements fit the port class and total budget. Models needing proprietary or passive powering methods must be considered separately. Some motorised cameras and higher-performance access points need PoE++ power. Check exact model specifications and test representative equipment before finalising a large deployment.
Does the switch include redundant power hardware?
Ubiquiti specifies compatibility with an external redundant DC power arrangement through its USP-RPS input. That does not establish that the external system is included with a particular quoted switch. Similarly, an external UPS is a separate system that must be sized and specified. Ask for the exact equipment list and expected failure behaviour before relying on a redundancy claim.
Can it be fitted in an outdoor rack?
It is a rackmount switch with published temperature and humidity operating limits and should be installed in a protected environment. An outdoor enclosure requires proper engineering for heat, dust, moisture, cable entry and electrical protection. Do not treat the switch itself as weatherproof. The suitability of a particular installation depends on real cabinet conditions and the complete equipment arrangement.
What information is needed for fiber uplinks?
Provide the required 1G or 10G rate, approximate distance, fiber type if known, connector arrangements and the interface model at the remote end. This helps determine whether suitable transceivers or direct-attach cabling are required. The switch’s SFP+ slots alone do not define module compatibility, optical reach or the material included in the sale. Test the complete link after installation.
Is it suitable for a large office or school?
It can be suitable where the actual endpoint count, PoE demand and uplink plan match the specifications. The surrounding network still needs an appropriate gateway, sufficient capacity and a maintainable management design. Some sites will require several switches, or multigigabit access ports that this model does not have. Build a port and power schedule from the actual project before selecting hardware.
How do I request a quote for Tanzania?
Send the exact model and required quantity, an endpoint inventory, PoE requirements, SFP+ link needs, site conditions and any special network policy or redundancy requirements. Ask FourTeck Tanzania to confirm the product package, compatible accessories, current local commercial terms and any requested services. Local availability, pricing, delivery and warranty conditions have not been asserted in this page content.
Request a quotation from FourTeck Tanzania
Share your USW-Pro-48-POE quantity, number of powered devices, maximum power requirements, uplink media, network diagram and installation context. Confirm the exact quoted model, applicable price, availability, accessories, delivery and support terms directly before purchasing. This request has no verified FourTeck destination link, so the call to action is intentionally non-linked.









Reviews
There are no reviews yet.