Ubiquiti UniFi • 10G / 25G network aggregation
Ubiquiti USW-Pro-Aggregation 32-Port Managed Switch
Build a high-speed aggregation layer for compatible access switches, servers and network storage with 28 10G SFP+ connections, four 25G SFP28 links and supported local Layer 3 functions. For the Ubiquiti USW-Pro-Aggregation Tanzania buying journey, plan optics, power, rack space and routing before requesting a project quotation.
28 × 10G SFP+ | 4 × 25G SFP28 | Layer 3 | 1U rackmount
Designed for busy 10G networks with selected 25G uplinks
The USW-Pro-Aggregation is a managed switching platform for organizations that need to collect many fast connections without moving every endpoint to 25G. It is most useful in rack-mounted networks where high-speed uplinks, server interfaces and structured fiber infrastructure already exist or are planned. It is not a PoE access switch, and compatible transceivers or cables must be specified for the installation.
A high-capacity aggregation layer, not an ordinary desktop switch
The Ubiquiti USW-Pro-Aggregation Tanzania buying decision starts with a practical question: how many fast links must your network bring together, and where does that traffic need to go? This switch is intended to sit between access-layer equipment, servers, storage and upstream network services. Its 28 SFP+ connections are suited to numerous 10G or 1G links, while four SFP28 connections can be used for higher-speed 25G links when both ends and the cabling support that speed. It is a central connectivity tool rather than a substitute for every other type of switch.
For a business building a new server room or upgrading several access switches, concentrating high-speed connections in one managed device can simplify the physical topology and the operational view. Yet its value depends on real port counts, compatible optics and sensible traffic engineering. A small office with only two 10G uplinks may be better served by a smaller aggregation model. A site that needs many copper RJ45 client ports or PoE for wireless access points should retain appropriate access switches and connect those to this aggregation layer.
What the 32 ports actually provide
The model offers 28 SFP+ cages rated for 1G and 10G, plus four SFP28 cages rated for 1G, 10G and 25G. A cage is a connection interface, not an already-installed fiber transceiver or a standard copper Ethernet socket. The chosen optic, direct-attach cable and remote equipment must support the intended speed. For example, an SFP+ port on an access switch could connect by a compatible 10G DAC when both devices are in the same rack, or by an optical transceiver and fiber when a longer route is required.
Do not treat the product as 32 interchangeable 25G ports. Only four positions are SFP28, and a sensible port plan reserves their capacity for links that actually benefit from 25G. Document the physical port number, link partner, expected operating speed and media before purchase. This simple practice highlights missing transceivers, speed mismatches and insufficient uplinks early, when changes are less disruptive than discovering them during commissioning.
Where 25G provides value
A 25G connection can help when multiple 10G sources converge toward a sufficiently capable core, virtualization host or storage system. It is particularly relevant when the remote network card, switch or storage interface already supports 25GbE and the application can use that bandwidth. The four SFP28 ports create room for selected higher-speed connections without making the entire network dependent on 25G equipment. The design can mix a broad 10G aggregation edge with a smaller number of faster links.
The connection must be engineered as an end-to-end path. Confirm the far-end interface, approved transceiver or DAC, fiber type, connector, distance, link negotiation and any forward error correction requirements. Do not assume a module labelled 25G will work with every remote device. Also verify the exact SFP28 port-speed configuration restrictions against the deployed UniFi software before promising mixed-speed operation. A negotiated link speed is only one part of performance; storage, firewall capacity and application behavior can still limit the result.
Switching capacity versus usable application speed
Ubiquiti specifies 760 Gbps switching capacity, 380 Gbps total non-blocking throughput and a forwarding rate of 565 million packets per second. These are different measurements. The switching-capacity figure is a duplex aggregate measure for the switching fabric, while the non-blocking throughput figure describes aggregate one-direction traffic capacity at the device level. Neither figure means one connected server can transfer data at 380 Gbps. Each connected endpoint remains limited by its port, protocol behavior and the complete network path.
In a design review, compare expected simultaneous traffic rather than adding every theoretical port rate and assuming all links stay saturated. Look at backup windows, large file transfers, virtualization migrations, surveillance recording and normal user activity. A 10G source feeding a 25G uplink may enjoy headroom, but several sources sharing a bottleneck still need careful placement. Test realistic workloads after installation and watch utilization, packet drops and application response. Headline speeds are useful for choosing the tier of hardware; disciplined capacity planning determines whether the deployed network feels fast.
Fiber modules, distance and optical budgeting
An optical network starts with media selection. Multimode and single-mode fiber serve different physical layouts, and optical transceivers must match both the fiber plant and the interfaces at the other end. Before ordering, record the cable type, connector standard, measured route length, patch-panel layout, number of intermediate connections and each transceiver specification. Matching the nominal data rate is not enough if the optics operate at incompatible wavelengths or the optical budget does not account for losses along the path.
For building-to-building or floor-to-floor connections, involve the cabling installer in the switch bill of materials. Ask for fiber certification or test results and maintain labels at both ends. Avoid quoting a fixed kilometer range as a property of the switch itself: reach is determined mainly by optics and fiber, not merely the presence of an SFP+ socket. Extra attention to dust caps, connector cleaning and bend radius protects the physical investment. The same principles apply whether the site is a campus, an office block or a purpose-built equipment room.
DAC, active optical cable and RJ45 adapter decisions
Short, same-rack connections are often candidates for direct-attach copper cables because they can reduce the need for separate optical modules. Active optical cables may be useful where the supported length or cable-handling requirements differ. Conventional fiber transceivers provide greater installation flexibility for patch panels and longer routes. Each option should be selected against the published compatibility of both connected devices, its length and environmental conditions; the cable alone does not guarantee that two unlike vendors will negotiate correctly.
The switch does not offer a bank of built-in RJ45 Ethernet ports. If a design requires copper 10G links, investigate supported SFP+ copper modules, including their power draw, thermal characteristics and compatibility. Copper modules can run hotter than optical or DAC alternatives, so avoid assuming every cage can be populated with any adapter without checking the manufacturer’s guidance. Where many end devices use RJ45, a suitable copper aggregation or access switch may be cleaner and less expensive than converting a large number of SFP+ interfaces.
VLAN segmentation for shared infrastructure
Managed VLANs allow an administrator to separate traffic logically while using the same physical aggregation hardware. A design might distinguish user services, server workloads, management interfaces, voice traffic and specialized equipment. A VLAN plan is most effective when the access switches, aggregation switch and gateway agree on which networks are carried on each tagged trunk. Document native or untagged VLAN treatment and allowed VLAN lists, rather than relying on defaults that may pass traffic more broadly than intended.
The USW-Pro-Aggregation supports VLAN-related functions and Ubiquiti lists up to 1,000 supported VLANs. That number is a technical ceiling, not a recommendation to create hundreds of networks without a purpose. Design segmentation around security, operations and broadcast domains. Restrict management connectivity, review how DHCP reaches each segment and validate that endpoints receive the expected address and policies. Where a local site has separate business units or technical tenants, segmentation should be backed by access controls and clear ownership, not simply by differently numbered VLANs.
Layer 3 features: useful, but scoped
This model supports Layer 3 functions including local inter-VLAN routing, IPv4 static routing, DHCP relay and a DHCP server for local networks. Ubiquiti lists a maximum of 256 IPv4 static routes. That makes the switch a candidate for certain local routing duties, particularly when selected internal networks exchange traffic. It does not mean it replaces a fully featured perimeter firewall, a sophisticated dynamic-routing core or an internet security appliance. Match the routing feature set to the intended topology and current UniFi software.
Before moving routing responsibilities from another device, write down gateway addresses, return routes, firewall boundaries, DHCP ownership and fault-recovery steps. A local inter-VLAN route can improve the clarity of an internal architecture, but it can also unintentionally bypass a security checkpoint if the traffic path is not reviewed. Run a controlled pilot for representative networks and confirm which policies are enforced on the aggregation switch versus upstream infrastructure. Design documents should identify exactly where routing and inspection happen, not leave these decisions implicit.
Traffic controls and access protection
Ubiquiti documents LACP link aggregation, STP and RSTP, DSCP-based QoS, IGMP snooping, port isolation, storm control, DHCP snooping and guarding, 802.1X control, access lists and port mirroring for this platform. These functions help teams manage how traffic enters and traverses the switching layer. They should be selected deliberately. For instance, loop prevention protects against accidental bridging paths, while port mirroring can support troubleshooting when a specific flow needs packet inspection.
Security comes from correct policies and consistent deployment, not merely from a long feature checklist. Define which devices are authorized on each port, how management access is restricted, what happens when authentication fails and who can modify a trunk. Validate ACL behavior in the actual UniFi version before claiming an isolation policy is complete. Keep the firewall responsible for the traffic inspection and protection tasks that belong there. Configurations should be tested after software upgrades because the supported controls and their interfaces may change over time.
Link aggregation and the difference from stacking
LACP can combine suitable physical links into a logical bundle between compatible devices. It is often useful for distributing many conversations across links and for retaining connectivity if an individual member fails, subject to how the other endpoint and topology are configured. It is not the same as making a single TCP transfer run at the arithmetic sum of all member ports. Many common hashing designs keep one flow on one physical member, so expectations must be based on the workload rather than the bundle’s total nominal capacity.
Equally important, do not confuse LACP with switch stacking or chassis-level high availability. A link bundle does not make one physical USW-Pro-Aggregation immune to a switch failure, software fault or maintenance event. If the site requires a resilient core with independently survivable switching nodes, explicitly evaluate the required architecture and whether the chosen products support it. Run failover tests that include a cable outage and, where relevant, a whole-device outage. Buy the availability architecture, not just an extra cable.
Power continuity and redundant-power planning
The device has a universal 100–240V AC input and a dedicated DC input designed for the UniFi SmartPower redundant power system. Ubiquiti states maximum power consumption of 100W. A compatible redundant-power unit is separate from the switch and should be included only when the project actually requires and provides it. The backup connector is valuable, but does not remove the need for correct power distribution, a suitable UPS where justified, and an understanding of what services remain running during a power disturbance.
For a Tanzanian installation, have the electrical and infrastructure teams review outlet provision, UPS runtime, earthing, surge protection and any applicable site-specific standards. Avoid assuming that the switch’s own backup input protects attached servers, routers or storage devices. A resilient aggregation layer also depends on a powered gateway, viable upstream path and functional cooling. Record which equipment is connected to which power source and practice a planned power-event test. This creates a much more meaningful business-continuity outcome than relying on an unchecked redundancy label.
Rack dimensions, mounting and cooling
The switch occupies 1U and measures 442 × 325 × 44 mm. Its weight is approximately 4.6 kg without mounting hardware and 4.7 kg with brackets. Ubiquiti lists a supported rack depth of 400–1200 mm, although the overall usable rack space must also accommodate cables, connectors and service access. Reserve enough clearance for optical cable management, patch leads and a sensible bend radius. Verify rail and rack compatibility, not merely the external height of the chassis.
Cooling matters in dense optical deployments. Ubiquiti specifies an operating ambient range of -5 to 40°C and 10% to 90% non-condensing relative humidity. A closed cabinet in a warm environment may exceed those conditions even when the room feels comfortable. Review airflow, dust control, rack fan strategy and the heat generated by nearby devices. Label every fiber run and avoid routing patch cords across fans or service access. Sound and fan considerations should also be checked for rooms near occupied offices; this is an equipment-room product, not a fanless desk accessory.
UniFi Network management and lifecycle
Ubiquiti specifies UniFi Network version 6.1.25 or later for the model. Centralized management can provide a consistent view of devices, ports and network configuration, but the actual software environment must be checked for support of each intended feature. Plan controller ownership, administrator roles, secure access, backups and a documented recovery route before the switch becomes a critical dependency. Make sure the UniFi application and the network hardware are maintained according to a tested change-management process.
The built-in 1.3-inch touchscreen is helpful for local device status, but it does not replace comprehensive monitoring. Maintain an inventory of device models, firmware, transceiver types and important configuration choices. Schedule updates in a maintenance window, test representative uplinks after changes and document a rollback or recovery plan. Operations staff should know how to identify a degraded link, unexpectedly blocked port or routing error. Good management discipline protects the investment long after the initial installation is finished.
A topology for multiple access switches
A common deployment puts the USW-Pro-Aggregation in the central rack and connects departmental or floor access switches into its 10G SFP+ ports. Those access switches continue to provide the copper connectivity and PoE that ordinary endpoints need. This separates device access from aggregation and gives the team a clearer place to observe higher-speed traffic. Some uplink ports may be reserved for the gateway, local servers, storage and future expansion, rather than consuming every port immediately.
Create a port-allocation worksheet before selecting the final design. Count every access-switch uplink, required redundancy path, server connection, monitoring port and spare. Decide whether traffic will be centralized in a single rack or routed elsewhere. A design that uses every 10G cage on installation day leaves little room for maintenance or growth. Include patch panel identifiers and cable media in the diagram. This documented topology helps procurement order the correct accessories and helps technicians avoid accidental cross-connections during a later move.
Server and virtualization connectivity
Virtualized hosts often carry several traffic classes: virtual-machine networks, management, storage access, migration and backup. The Pro Aggregation can bring high-speed server NICs into a common managed switching layer when the servers expose supported 10G or 25G interfaces. VLANs can organize these paths, while uplink choices should reflect workload peaks and storage sensitivity. A 25G slot is especially worth evaluating for a host or service with measured demand beyond an ordinary 10G connection.
A credible server design checks hypervisor support, NIC firmware, transceiver compatibility, teaming approach and the role of each virtual switch. Do not assume that placing two network interfaces in one host automatically doubles every workload’s speed or creates full service resilience. Measure the dominant traffic flows and understand what happens when an uplink or aggregation switch fails. For clustered environments, follow the platform vendor’s guidance for storage and heartbeat paths. The network switch is one component of the broader application availability design.
Network storage, backups and large-file workloads
NAS and backup systems can generate sustained traffic that looks very different from everyday web browsing. Bringing multiple servers and a storage target into a 10G aggregation fabric may help reduce congestion when disks, CPUs and storage protocols are capable of keeping up. One or more selected 25G links can provide additional headroom where the storage system and remote NICs support it. The potential improvement is governed by the entire transfer path rather than just the model’s advertised switching capacity.
Assess capacity through test cases such as a full backup, restore exercise, concurrent media ingest or virtual-machine migration. Check whether backup jobs collide with business-hour demand and whether a shared uplink becomes the real constraint. Large MTU settings, link aggregation or traffic-class adjustments should be introduced only after compatibility and end-to-end behavior are validated. Keep an eye on packet loss and latency, because a network that looks fast in a simple bulk transfer can still create a poor experience for sensitive production applications.
Video production and professional AV traffic
The manufacturer’s current feature list includes Pro AV profiles alongside advanced multicast controls and IGMP functions. These features may be relevant when supporting professional media systems that use high-volume multicast or carefully managed network paths. A video-production network should nevertheless be designed around the specific equipment and its vendor’s requirements. Different AV-over-IP technologies use different timing, bandwidth and multicast patterns, and not all of them are interchangeable merely because the switching platform advertises an AV profile.
Before deployment, map sender and receiver counts, peak stream rates, multicast groups, control-plane needs, clocking or synchronization requirements and oversubscription assumptions. Confirm that the chosen AV platform is supported by the intended switch software and port speeds. Separate critical media traffic from general office noise when appropriate, and conduct a sustained test using realistic streams. Treat the supported profiles as configuration aids rather than blanket compatibility endorsements for every camera, encoder, decoder or media workflow.
Campus links and connections between equipment rooms
Institutions with multiple wiring closets may use an aggregation switch to collect trunks from remote access switches. The 10G SFP+ count makes the model interesting when several closets need dedicated high-speed links, while SFP28 can serve selected core or distribution connections. The appropriate media depends on route length, fiber availability and the counterpart hardware. Long or exposed cabling routes deserve attention to route diversity, protection and maintenance access rather than only to the advertised data rate.
A practical campus design should start with a building map, a fiber schedule and a capacity forecast for each closet. Identify any single conduit or distribution point whose failure would affect multiple areas. Verify whether separate links actually use separate paths; two fibers in one damaged cable do not give true physical diversity. Also define the gateway location, inter-VLAN routing point and security boundary. A well-documented campus aggregation plan makes later switch additions more predictable, especially when multiple installation teams work across the same facility.
Why this model does not deliver PoE to endpoints
An important limitation is the absence of PoE output ports. The USW-Pro-Aggregation is a high-speed SFP-based switch, so it is not intended to power wireless access points, IP cameras, telephones or other Ethernet-powered devices directly. These endpoints generally remain attached to appropriate PoE access switches or to other approved power arrangements. The aggregation device then carries their upstream traffic. This distinction avoids a costly procurement mistake when a buyer sees ’32-port switch’ and assumes it can replace an existing PoE access switch.
Similarly, the presence of an SFP+ cage does not make it a conventional RJ45 port. An endpoint with only 1G copper Ethernet should normally be connected through suitable access infrastructure. In the product bill of materials, show which hardware provides endpoint power, which equipment performs aggregation and which device handles security and internet access. This keeps the network modular. It also lets engineers select each tier for its actual job rather than forcing one product to cover functions it was not designed to provide.
Practical Tanzania project considerations
For a Tanzania-based network project, the design should reflect the site’s own infrastructure and operational constraints instead of assuming an identical installation everywhere. Ask about available rack space, power quality, generator or UPS arrangements, cooling, indoor dust conditions, optical fiber pathways and access for maintenance. Where staff or branch users depend on a connection across an external provider, remember that local switching capacity cannot compensate for insufficient contracted WAN bandwidth. Confirm service requirements separately with the relevant connectivity provider.
Commercial planning needs equally careful verification. The requested model name is not proof of stock, delivery time, warranty terms or a local regulatory status. Request current confirmation of the exact model, included items, compatible optics, commercial terms and shipping arrangements from the intended seller. Do not base a purchase on a foreign online price converted to Tanzanian shillings. If the installation is for a regulated or safety-critical environment, the procuring organization should also verify any applicable local approval and procurement obligations before deployment.
A useful bill of materials goes beyond the switch
A correct quotation should identify more than one 1U chassis. Include the number of 10G and 25G links, exact cable or optic type for each, optical patching, fiber adapters, compatible remote interfaces, rack accessories and any required backup-power equipment. Factor in spare optics and suitable labeling materials where service continuity matters. A list that simply says ‘thirty-two ports’ can conceal significant accessory costs and leave the installation team short of essential components on the commissioning date.
Also account for work that is not physically inside the switch carton: fiber testing, rack space preparation, safe cable routing, electrical provision, network design, configuration, security review and acceptance testing. Specify responsibility for every task and ask which work is included in the supplier’s price. Where an existing network will be migrated, plan a rollback route and a period for confirming link stability. This method produces a clearer project budget and helps compare quotations on a like-for-like basis.
Questions to ask before requesting a quote
Start with the current network diagram. How many 10G links are needed today? How many might be needed during the equipment’s planned service life? Which four connections, if any, genuinely need 25G? Does the receiving equipment already support SFP28? Are the links within a rack or across installed fiber? Which VLANs, routes and security boundaries will be present? Answers to these questions determine whether this switch is the right tier and prevent a misleading comparison based purely on port counts.
Then consider operations. Who controls UniFi Network, performs upgrades, manages backups and responds to outages? Is an optional power-backup unit required? What are the acceptable downtime and recovery expectations? Must the solution remain available while an aggregation switch is replaced? If so, a single-chassis design may not be sufficient. Finally ask the supplier to validate optics, confirm the exact unit identity, state local commercial terms and provide a quotation that lists exclusions clearly. A good purchasing conversation makes the installation scope explicit.
Deployment sequence: from design to adoption
A controlled installation begins before any fiber is plugged in. Confirm the intended controller version, network plan, equipment inventory and maintenance window. Check rack suitability and power conditions, then mount and label the switch using appropriate procedures. Prepare a port map containing the remote device, speed, media and VLAN policy for every connection. Test the management path first so the switch can be adopted and configured without exposing production networks to an unfinished policy.
Next bring up uplinks in a deliberate order. Confirm physical link and negotiated speeds, then apply or verify tagged VLANs, DHCP behavior, static routes and any required access controls. Test a representative endpoint in each important segment and ensure internet-bound traffic follows the intended security path. For LACP bundles or secondary links, verify failure behavior before handing over the system. Capture baseline monitoring results, configuration information and as-built diagrams. This phased approach reduces troubleshooting time because each new dependency is introduced and confirmed separately.
Acceptance testing that proves the deployment works
A successful boot screen is not the same as a successfully commissioned aggregation network. An acceptance checklist should confirm that all intended ports are labeled, the correct modules are installed, links negotiate at their planned speeds and live traffic follows the documented topology. Test connectivity within approved VLANs and verify that traffic between separated segments is permitted or denied as designed. Check DHCP, default gateways and any configured static routes with real test devices rather than assumptions.
Where resilience matters, deliberately disconnect a link, test the expected failover and record the result. Exercise monitoring alerts and verify that authorized administrators can recover access. Use appropriately sized throughput tests between capable endpoints, observing device interfaces and errors while the traffic runs. Note that a speed test limited by a laptop or storage drive does not demonstrate the switch’s full capability. Close the project with an updated diagram, firmware record, optical inventory and clear ownership of future change requests.
Monitoring and troubleshooting high-speed uplinks
High-speed aggregation issues can appear as intermittent drops, wrong negotiated speeds, asymmetric reachability, congestion or unexpectedly poor application performance. Investigate from the physical layer upward. Check transceiver compatibility, optical condition, cable labeling and the link partner before changing routing policies at random. Look for port errors, excessive utilization, blocked states, misconfigured trunks and inconsistent LACP groups. Recording what changed immediately before the problem began can greatly narrow the search.
Use port mirroring and traffic observation where appropriate, while protecting sensitive business data during diagnostics. Keep device and controller versions documented and record any confirmed interoperability quirk for the installed modules. A disciplined incident log should capture symptoms, affected services, tested hypotheses and the final fix. This turns a one-off troubleshooting exercise into durable operational knowledge. It is especially useful in facilities where different teams maintain the fiber plant, server environment and managed switching equipment.
Choosing between UniFi aggregation models
Ubiquiti also offers a smaller Switch Aggregation with eight 10G SFP+ ports, which may be enough for modest networks that do not need the Pro model’s higher port count or selected 25G links. At the other end, newer higher-capacity aggregation families address designs demanding many 25G connections or additional core-network capabilities. The correct comparison should focus on real interface mix, feature support, availability architecture, expected growth and total project cost, rather than selecting the highest specification by default.
The USW-Pro-Aggregation is a strong candidate when the requirement is primarily numerous 10G trunks with a limited number of 25G links. It is less suited when the majority of the endpoints are RJ45 devices, when direct PoE is mandatory, or when true multi-chassis redundancy and sophisticated data-center routing are hard requirements. Ask the network designer to compare at least one appropriately sized alternative and document why the chosen model satisfies the specific deployment. That creates a better decision record for future upgrades.
Growth planning without speculative upgrades
Reserve headroom according to identifiable needs, not vague predictions. If additional access switches, servers or production systems are already on the roadmap, account for those connections in the initial port allocation. Preserve a sensible number of spare 10G cages and avoid assigning all four 25G connections to temporary purposes. A simple forecast by room, workload or project phase can show when the current uplink topology may become congested. It can also reveal whether a higher-tier aggregation switch would avoid an early second purchase.
Growth is not only about physical ports. Review future VLAN needs, security segmentation, maintenance workload, power capacity and cooling. Check the long-term software support requirements of the UniFi environment at the time of purchase, without assuming that a particular future feature or lifespan is guaranteed. Make modifications through a documented change process and retain known-good configurations. A network that is easy to understand and safely expand will often deliver more business value than an oversized platform whose interfaces and dependencies were poorly planned.
Total cost of ownership and operational fit
The purchase price of the switch is only one part of the cost. Optical modules, DAC cables, fiber patching, rack space, UPS capacity, cooling, installation work, configuration and ongoing maintenance can materially affect the final budget. The number of required ports at each speed is a practical cost driver: a site that can use short supported DAC connections may have a different accessory budget from one spanning several buildings with optical links. Compare itemized bills of materials rather than headline switch prices.
Operational familiarity matters too. An organization already managing UniFi networks may benefit from a familiar administrative workflow, provided the platform’s routing and availability features suit the task. A team needing advanced data-center functions should verify those requirements rather than assume a product marketed as Layer 3 includes every enterprise protocol. Before approval, identify who will own configuration, patching, monitoring and incident response. The right platform fits not just the technical topology, but also the people and processes responsible for keeping it available.
Documenting a secure handover
At the end of installation, the owner should receive a concise as-built pack: rack diagram, port map, patch-panel and fiber identifiers, VLAN plan, management access procedure, device and software versions, and a summary of applied routing and security policies. The pack should explain any deliberate exceptions, such as unused ports left disabled or specific trunk permissions. Keep credentials and recovery secrets in an approved secure system rather than embedding them in a general document.
Include test records for representative speeds, connectivity, management access and any required failover scenario. Clearly identify which accessories are installed and which optional components were not purchased. Record warranty and supplier contacts only after they are verified for the actual transaction, not copied from an unrelated market. This documentation supports training, audit readiness and faster troubleshooting. It also makes future hardware replacement less dependent on the memory of the original installer.
Verified technical specification overview
Manufacturer-listed values for the exact USW-Pro-Aggregation model. Check the relevant software release and selected accessories before deployment.
| Model | USW-Pro-Aggregation |
|---|---|
| Brand | Ubiquiti / UniFi |
| Form factor | 1U rack mount |
| 10G ports | 28 × SFP+ (1G/10G) |
| 25G ports | 4 × SFP28 (1G/10G/25G) |
| Switching capacity | 760 Gbps |
| Total non-blocking throughput | 380 Gbps |
| Forwarding rate | 565 Mpps |
| VLANs | Up to 1,000 |
| MAC address table | 32,000 |
| IPv4 static routes | 256 |
| Packet buffer | 4 MB |
| Maximum power consumption | 100W |
| Power inputs | 100–240V AC plus optional USP-RPS DC backup input |
| Dimensions | 442 × 325 × 44 mm |
| Weight | 4.6 kg without rack brackets |
| Operating temperature | -5°C to 40°C |
| UniFi Network requirement | 6.1.25 or later |
| RJ45 and PoE | No native RJ45 switching ports; no PoE output |
Frequently asked questions
Is the USW-Pro-Aggregation a 32-port 10G switch?
It has 32 physical transceiver cages, but they are not all identical: 28 are SFP+ interfaces supporting 1G or 10G, and four are SFP28 interfaces supporting 1G, 10G or 25G. Describe the model as a 28-port 10G plus four-port 25G aggregation switch when purchasing accessories. Its chassis does not provide conventional copper RJ45 end-user ports.
Can it connect to 1G switches?
The manufacturer lists 1G support on its SFP+ and SFP28 interfaces. A working connection still requires a compatible module or other supported media and a matching port on the remote device. Verify negotiation, optical specifications and the actual UniFi configuration. If a large number of access devices operate only at copper gigabit speeds, aggregate them through suitable access switches instead of attempting unnecessary module conversions.
Does this switch provide Power over Ethernet?
No. It is not a PoE access switch. Wireless access points, IP cameras and VoIP handsets that need PoE require an appropriate power source, commonly a PoE access switch. The Pro Aggregation unit can aggregate uplinks from those access switches. Treat endpoint power budgets and uplink capacity as separate design questions to avoid choosing equipment that cannot power your installed devices.
Does it support routing between VLANs?
Yes, Ubiquiti documents local inter-VLAN routing, IPv4 static routes, DHCP relay and DHCP service for local networks. The precise fit depends on your routing design and supported UniFi software. It should not automatically replace the organization’s firewall or a router that provides advanced routing and security services. Confirm gateways, traffic inspection paths, access policies and return routes before enabling routing in production.
What speed do the four SFP28 ports support?
Ubiquiti lists 1G, 10G and 25G speed support for the four SFP28 connections. The actual operating speed depends on both link partners and compatible media. Review relevant port-group speed restrictions and firmware behavior before using a mixture of modes, especially when one or more links operate at 25G. Conduct a physical link test with the chosen modules rather than treating theoretical support as proof of interoperability.
What are switching capacity and non-blocking throughput?
The manufacturer states 760 Gbps switching capacity and 380 Gbps total non-blocking throughput. These aggregate fabric measures are not the speed of an individual server or a guarantee for a specific workload. Actual results depend on port rates, traffic distribution, endpoint hardware, protocols and any congestion elsewhere. For procurement, examine the traffic flows the switch will actually carry and test them after installation.
Can the switch connect servers and NAS devices?
Yes, when their network interfaces and chosen transceivers or cables are compatible. It is commonly relevant to 10G server aggregation and selected 25G storage or virtualization links. Before ordering, verify NIC support, optical compatibility, switch configuration, host bonding requirements and the expected demand. A high-speed port alone does not guarantee that storage disks, virtual machines or backup jobs can fill it.
Does it have a redundant power supply?
The unit has an AC power input and a connector for a compatible UniFi SmartPower redundant-power system. Backup equipment is a separate requirement, not something that should be assumed to be included. A resilient installation may also need a UPS, sensible power distribution and backup arrangements for neighboring equipment. Ask the supplier to state exactly what redundancy components are included in the proposed quotation.
Can I install it in any network cabinet?
It uses a 1U rack-mount chassis measuring 442 by 325 by 44 mm, but cabinet compatibility also depends on usable depth, mounting hardware, fiber-cable management, airflow and service clearance. Ubiquiti lists a rack-depth range and an operating ambient limit up to 40°C. Check the real cabinet and environment before purchase, especially for densely populated equipment rooms.
How is the switch managed?
It is managed through the UniFi Network ecosystem. Ubiquiti specifies version 6.1.25 or later as the baseline application requirement, while specific features may depend on the installed software. Plan adoption, administrator access, configuration backups, monitoring and update procedures. The local touchscreen helps with device status, but secure centralized operations and documented recovery remain important.
Does buying this switch include fiber optics and installation?
Do not assume so. The switch, optical transceivers, direct-attach cables, fiber testing, rack accessories, backup-power equipment and professional installation should be itemized in the quotation. Confirm each included item and service with the seller. The correct mix depends on link speeds, distance, installed fiber, remote equipment and site conditions; a generic bundle may not fit the intended network.
How can I request a quote in Tanzania?
Provide the exact model USW-Pro-Aggregation, required quantity, list of 10G and 25G connections, link distances, rack and power details, and desired deployment scope. Ask FourTeck Tanzania to confirm the target product, accessory compatibility, current commercial terms and availability. No local price, stock status, delivery commitment or regulatory approval should be inferred from this informational product description.
Request a project-specific USW-Pro-Aggregation quotation
Tell FourTeck Tanzania the quantity of switches, the number and distance of 10G or 25G links, the remote equipment, and the rack and power conditions. Request confirmation of the compatible module and cable list, current stock status, price, warranty terms, shipping arrangements and any installation scope. The quotation should describe the exact package before an order is placed.
Ask FourTeck Tanzania for a verified solution quote.







Reviews
There are no reviews yet.