UniFi managed switching | Tanzania product guide
Ubiquiti Pro Max 24 PoE — a powerful 24-port access switch with a balanced mix of speed and PoE
The Ubiquiti Pro Max 24 PoE USW-Pro-Max-24-PoE is designed for business networks that need centralized switching, higher-power PoE and selected multi-gigabit access ports. It is well suited for evaluation in structured office, WiFi, surveillance and professional AV designs. Check your device count, power schedule and network topology before choosing it.
Request a model-specific quotation and confirm the matching accessories, current commercial terms and local availability.
At a glance: the exact port mix
| Interface group | Count | Capabilities |
|---|---|---|
| 1 GbE RJ45 | 8 | PoE+ output |
| 1 GbE RJ45 | 8 | PoE++ output |
| 2.5 GbE RJ45 | 8 | PoE++ output |
| 10G SFP+ | 2 | High-speed uplinks; no PoE |
PoE power is shared across the switch. The 400W total is separate from each port’s individual power-class limit. This product description describes model capabilities, not verified stock or a Tanzania-specific offer.
What this switch solves for a growing network
The Pro Max 24 PoE is aimed at network administrators who need more than an unmanaged collection of Ethernet ports. A typical business may have office computers, WiFi access points, security cameras, meeting-room equipment, voice endpoints and uplinks to servers competing for rack space and power sockets. Bringing compatible devices onto a managed PoE access switch can simplify cabling, centralize visibility and make changes more deliberate. The important design question is not merely whether the switch has 24 ports. It is whether the mix of 1 GbE, 2.5 GbE, PoE+ and PoE++ interfaces suits the actual equipment list, its expected traffic and its peak electrical load.
This model offers eight 2.5 GbE PoE++ ports, another eight 1 GbE PoE++ ports and eight 1 GbE PoE+ ports, plus two 10G SFP+ connections for uplinks. That is a useful mix for many small and midsize wiring closets, but it does not provide 2.5 GbE on every copper port. Buyers should map specific devices to specific port groups before deciding that it is the right switch.
Understand the 24 RJ45 ports before assigning equipment
All 24 copper Ethernet interfaces can supply standards-based PoE to suitable powered devices, but they are not identical. The eight multi-gigabit ports negotiate up to 2.5 GbE and support PoE++; eight additional Gigabit ports support PoE++; and the remaining eight Gigabit ports support PoE+. This distinction matters when assigning an access point with a multi-gigabit network interface, a higher-power security camera or a simple desk phone. A 2.5 GbE access point connected to a Gigabit-only port may still operate, but the switch-side wired link is limited by that slower port. Likewise, a device that requires the higher PoE++ power class needs to be placed on a compatible output.
Prepare a port schedule with endpoint name, link speed, PoE standard, expected watts, VLAN and physical patch-panel location. Keep spare ports for maintenance and expansion rather than assuming that every socket can be committed permanently. The two SFP+ uplinks are additional interfaces; they are not extra RJ45 PoE outputs.
Why the eight 2.5 GbE connections are valuable
Multi-gigabit access ports help where a single endpoint can genuinely transfer more than one gigabit per second through its wired interface. Examples include suitably equipped higher-capacity wireless access points, workstations with matching Ethernet adapters and specialized network devices. They can be especially useful when a business upgrades its WiFi equipment but wants to keep the rest of its wired endpoints on ordinary Gigabit Ethernet. The Pro Max 24 PoE provides a targeted multi-gigabit zone instead of requiring every copper port to operate at 2.5 GbE.
A 2.5 GbE label does not guarantee an observed 2.5 Gbps application speed. Both connected devices must support the negotiated rate, the cable path must be sound, and the wider network, security gateway, servers and workload must be capable of using the capacity. Consider whether only eight such ports will be enough over the expected service life. If most endpoints already require multi-gigabit access, a model with a larger number of 2.5 GbE ports may offer a better fit.
Plan PoE power as a shared budget, not 24 independent maximums
The switch offers a total available PoE budget of 400W. Its PoE++ ports can supply up to 60W per port under the supported standard, while its PoE+ group is designed for compatible lower-power devices. The 400W number is shared across the whole switch: it is not 400W on every connection, and it is not possible to run every PoE++ port at its maximum simultaneously. A high-power camera, access point or other endpoint must satisfy both the individual port rating and the total available budget.
For accurate planning, consult each powered device’s own technical specification for required PoE mode, typical draw and maximum draw. Build the power schedule using plausible peak demand rather than only idle measurements. Also decide what should remain powered if equipment is added later. A network that starts below its budget may exceed the budget after an access-point upgrade or the addition of motorized cameras. The right procurement decision leaves meaningful operating margin instead of matching the theoretical total exactly.
Illustrative PoE calculation and headroom
Consider a hypothetical equipment mix of six access points allowed 20W each, four cameras allowed 35W each, six modest PoE endpoints allowed 12W each and two small devices allowed 10W each. The planning total is 120W plus 140W plus 72W plus 20W, or 352W. Against a 400W shared budget, that leaves 48W of calculated margin. These numbers are a worked example, not measured consumption figures for any specific products. Real devices may draw differently, and their maximum power classifications should determine the final calculation.
The example uses 18 copper ports, leaving six physically unused, but available sockets do not create extra electrical headroom. Conversely, 24 connected low-power devices may fit within the budget if their individual demands and port standards permit it. Document the load per group, avoid allocating PoE++ endpoints to PoE+-only interfaces, and review the design whenever endpoints are changed. If the plan already approaches 400W, consider additional power capacity elsewhere in the network rather than relying on an optimistic average.
Use the two 10G SFP+ uplinks deliberately
Two 10G SFP+ ports provide a way to connect this access switch to a compatible distribution switch, aggregation layer or other suitable 10G network endpoint. They can be helpful when traffic from multiple cameras, WiFi access points or workstations is concentrated into a smaller number of upstream links. An uplink design should consider expected aggregate traffic, the path toward shared storage, the router or firewall and whether simultaneous device activity will be common.
SFP+ describes the port form factor and supported network interface; it does not mean a transceiver, fiber run or direct-attach cable is automatically supplied. Match the optical module or cable to the connected equipment, fiber type, connector, distance and supported settings. Plan link redundancy only after confirming the topology and configuration on both ends. Two physical uplink ports do not by themselves guarantee failover, zero packet loss or double the throughput of every client session.
Read performance figures in their proper context
Ubiquiti specifies 112 Gbps switching capacity, 56 Gbps total non-blocking throughput and a forwarding rate of approximately 83 million packets per second for this model. These are hardware switching figures that describe different aspects of forwarding capability. They should not be presented as the internet speed every attached device will receive or as a promise of application performance. Actual transfers depend on source and destination, link negotiation, packet sizes, policy settings, congestion, upstream connectivity and endpoint processing.
For a buyer, the useful takeaway is that the switch is designed to aggregate a mixture of Gigabit and multi-gigabit traffic with 10G uplinks. It is still necessary to calculate bottlenecks along the entire path. A 1 GbE endpoint cannot send at 2.5 GbE simply because the switch supports that speed elsewhere. A slow storage system, constrained WAN service or overloaded firewall can remain the limiting element even if the access layer has ample switching capability.
Layer 2 controls for organized business networks
This is a managed switch with features such as VLAN handling, link aggregation using LACP, spanning-tree support, IGMP snooping, port isolation, traffic controls, 802.1X control and port mirroring. Different organizations use different subsets of these tools. A simple office might need well-labelled VLANs and a few secure uplink ports; a larger installation may require a detailed multicast policy, monitoring sessions and authentication rules. A configuration is only effective when it matches the upstream switching, gateway and endpoint environment.
Layer 2 configuration deserves careful documentation because small changes can have broad consequences. Removing a needed tagged VLAN from an uplink can disconnect an access point or remote management network. Unplanned aggregation settings can introduce outages, while poorly considered port isolation can stop required device-to-device communication. Before deployment, define naming conventions and save a port-by-port configuration record. Test changes on a limited portion of the network before applying them to every access port.
Layer 3 capabilities and their boundaries
The Pro Max 24 PoE supports local Layer 3 functions, including inter-VLAN routing, static routing, DHCP relay and DHCP server capabilities for supported local network configurations. These options can be useful when selected traffic needs to move between appropriately configured internal networks. However, the presence of Layer 3 features does not turn this switch into a complete internet-edge firewall, security gateway or replacement for all routing services. The broader topology still determines where WAN connectivity, NAT, security inspection, remote access and internet policy are implemented.
When planning routing, establish which device owns each gateway address, which VLANs should be locally routed and which traffic should traverse a dedicated security enforcement point. Confirm controller and gateway compatibility before choosing a design. Network isolation and access-control behaviour can depend on where routing occurs. For regulated, multi-site or higher-security environments, document the intended trust boundaries and have a qualified administrator review routing and ACL policies instead of assuming that default settings provide the required protections.
VLAN design for staff, guests and connected devices
Business networks often benefit from separating categories of devices into logical networks. Staff computers may need business application access, guest WiFi may require internet-only connectivity, surveillance cameras may talk chiefly to recording services, and management interfaces may need restricted administrator access. VLANs offer a method of segmentation, but the isolation outcome depends on routing and access rules as well as switch-port membership. A VLAN tag alone is not a complete security policy.
Design the VLAN plan before configuring the rack. Give each network an understandable name, define the native or untagged assignment on endpoint ports and identify which VLANs must be carried across each switch or access-point uplink. Include DHCP services, DNS, management addressing and the path to the gateway in the plan. Test both permitted and prohibited communication after implementation. A documented segmentation plan is easier to troubleshoot and revise than a collection of ad hoc port changes made whenever a new printer, camera or access point is installed.
Traffic treatment, voice and latency-sensitive applications
The supported feature set includes QoS functions and controls for managing traffic behaviour. These can help administrators apply deliberate treatment to voice endpoints, application flows and other classes of network activity. They are not a universal cure for a saturated connection. A voice call may still suffer when the upstream WAN is overcommitted or when an endpoint is connected through a poor cable. Effective quality-of-service design must consider classification, queue behaviour and the points at which congestion actually occurs.
Voice VLAN, LLDP-MED and rate-control capabilities can simplify some business-phone deployments when the phones and the wider network use compatible settings. For real-time video or collaboration systems, review the required multicast handling and any vendor guidance. Keep configuration consistent across the path, especially where traffic passes through a gateway or into another switch. Measure results during busy periods rather than judging an installation by an idle-speed test alone.
Etherlighting and the on-device status display
UniFi Etherlighting adds visual assistance at the front of the rack. The system can illuminate compatible switch ports to indicate information associated with port location, link status, speed and native network assignment. This is particularly useful when a technician must identify one cable among many or investigate a changed connection without disconnecting the wrong device. Ubiquiti notes that compatible Etherlighting patch cables provide the best intended lighting experience; the full visual effect should not be assumed with every ordinary cable.
A 1.3-inch touchscreen status display adds another local reference point for servicing the switch. Neither the illuminated ports nor the display replaces a disciplined patch-panel schedule, accurate rack labels or monitoring records. Treat them as aids to support work, not as substitutes for documentation. In a shared equipment room, a consistent label format and a current port map are often as valuable as the hardware features when a fault needs to be isolated quickly.
Centralized operation through UniFi Network
The switch is intended to be configured and monitored through the UniFi Network management environment. Ubiquiti lists UniFi Network version 8.0.24 or later as the application requirement for the Pro Max 24 PoE. Businesses using older controllers should verify their planned upgrade path before connecting the switch, particularly when several sites or different generations of UniFi equipment are involved. Controller accessibility, adoption connectivity and management permissions form part of the deployment, not an optional afterthought.
A centralized management approach can make it easier to see connected devices, organize port profiles, review topology and carry out controlled configuration changes. It still requires suitable access controls and a planned operational process. Back up configuration where supported, protect administrator credentials, document who may modify switch settings and schedule firmware changes to minimize disruption. If a remote site depends on the connection being changed, ensure there is a practical recovery plan before updating its uplink or management VLAN.
Where Pro AV profiles can make a difference
Ubiquiti lists Pro AV profiles and advanced multicast controls among this switch’s software capabilities. Examples of supported profile ecosystems include Dante, Q-SYS, NDI, AES67, Shure, Crestron and related audiovisual workflows. For a meeting venue, control room, training environment or media installation, this can be a useful starting point when the network carries audio and video flows with specific latency, multicast or discovery requirements. The name of a profile is not proof that every device, firmware version or project topology will work without further testing.
AV network design should begin with the actual system integrator’s traffic recommendations. Determine whether the application uses multicast, how discovery operates across VLANs, which ports need specific QoS treatment and whether endpoint speeds or uplink capacity are sufficient. In mixed office and AV networks, consider separating traffic logically or physically where operational needs justify it. Validate the configuration with a representative production workflow instead of assuming that enabling a profile completes commissioning.
WiFi access-point deployment planning
One practical reason to choose this model is the combination of PoE++ and eight 2.5 GbE ports for selected wireless access points. A suitable multi-gigabit AP can receive network connectivity and compatible power over one Ethernet run, reducing the need for an outlet close to the AP location. But the correct port choice depends on the AP’s Ethernet speed, PoE requirements and any uplink or controller prerequisites. An access point that supports only 1 GbE does not automatically benefit from being assigned to a 2.5 GbE port.
Create an AP schedule that includes model, location, expected client density, upstream link requirement, maximum input power and the intended management and user VLANs. Consider whether the eight multi-gigabit ports should all be reserved for current APs or whether some should be held for future wireless upgrades. Confirm the cable route and terminating hardware, especially for ceiling installations with long paths or difficult access. Wireless performance also depends on radio planning, interference, client devices and internet capacity; the switch alone cannot guarantee WiFi speed or coverage.
IP cameras, security equipment and recording traffic
The switch can be considered for compatible PoE IP cameras, including selected devices with higher power requirements, provided each camera’s input standard matches the assigned output. Camera specifications vary considerably: a fixed camera may be comparatively modest, while equipment with motorized movement, illumination, heating or other accessories can draw substantially more power under certain conditions. The PoE design should use the manufacturer’s stated maximum requirement rather than an approximate category average.
For video surveillance, calculate both total power and recorded network traffic. Multiple cameras can create a sustained upstream load toward an NVR or storage server, even when users are not actively viewing live video. Decide whether the 10G uplink arrangement suits the recorder and aggregation infrastructure, and isolate camera management access where appropriate. This switch is a connectivity and power device; it does not contain an NVR or replace recording storage, camera licensing, access policies or system maintenance.
Office networks with mixed endpoint requirements
A medium-sized office can have varied needs across the same floor: ordinary PCs and printers, IP telephones, meeting-room AV controllers, a handful of newer WiFi access points and a few high-power devices. The Pro Max 24 PoE is designed around that mixed profile. Assign the multi-gigabit ports to devices that can use them, place suitable standard-PoE endpoints on the Gigabit groups and use the SFP+ interfaces to connect toward the broader network. This targeted approach avoids spending multi-gigabit switch ports on endpoints that have no reason to use them.
The design still needs sufficient port count for growth and a maintenance strategy. If an office expects more than 24 wired powered endpoints soon, include expansion in the network plan rather than relying on last-minute daisy-chaining. Similarly, if several servers or powerful workstations require 10 GbE copper access, this model’s 10G SFP+ uplinks do not make it a full 10G access switch. Define the actual devices first and choose the switch around those requirements.
School, hospitality and shared-facility considerations
In an education, accommodation or shared-facility environment, many endpoints may have similar physical requirements but very different traffic and security roles. Wireless access points, administrative equipment, cameras, phones and audiovisual endpoints should be inventoried separately. A managed PoE switch can simplify rack organization and monitoring, while the available VLAN and access features can support an intentional network structure. The switch’s relevance depends on the wiring layout, power demand, support staffing and upstream architecture rather than simply the type of building.
For example, a floor distribution cabinet may need to support several APs and security cameras while maintaining a reliable uplink to a central network room. The two 10G SFP+ ports may suit that design if the corresponding aggregation equipment and physical media are compatible. Where uptime requirements are high, document recovery procedures, keep configuration records and decide whether a second switch or alternate path is required. A single access switch remains a potential service interruption point regardless of its management features.
Connectors, optics and patch infrastructure
The choice of physical cabling is a purchasing decision, not a minor installation detail. Copper endpoints need sound Ethernet terminations and cables appropriate for the target negotiated rate and installation conditions. SFP+ uplinks need a compatible connection method, which may be a supported direct-attach cable or a suitable optical transceiver and fiber path. Each end must be planned together. A working physical connection at one speed does not automatically prove that a chosen module and distance will operate at another speed.
Before finalizing a bill of materials, record connector types, cable routes, patch-panel positions, fiber type if used, estimated run lengths and rack-to-rack access. Verify transceiver support for the equipment at both ends and confirm whether any modules or accessories are separate purchases. Clear labelling helps avoid avoidable errors during maintenance. Where existing cable infrastructure is reused, plan testing rather than assuming its documented category still describes the installed channel accurately.
Security controls must be part of a wider architecture
This switch provides managed access-layer features that can support network hygiene, including 802.1X control, ACL-related functions, device isolation, DHCP snooping and port restrictions. These features are useful only when configured for a specific access policy. A secure deployment starts with management-account protection, an approved administration path, consistent firmware practices, documented VLAN membership and a clear boundary between trusted and untrusted endpoints. It also requires an appropriate firewall or gateway arrangement for traffic that needs broader inspection.
If a camera network is intended to be isolated from guest devices, test that traffic is actually blocked across the routing points involved. If an authentication service is introduced, plan how devices recover when that service is temporarily unavailable. Consider the risks of default credentials, exposed management interfaces and unused active ports. The switch can be an important enforcement point, but no single checkbox should be described as a complete security solution.
Power resilience and what DC backup readiness means
The model includes an AC power input and a compatible USP-RPS DC input for an optional redundant-power arrangement. This is a useful infrastructure option for deployments that need an additional power path. It does not mean a backup unit, battery or uninterruptible power supply is included with every switch purchase. Nor does it eliminate the need to plan the upstream electrical supply, switch room power distribution and duration of any required outage protection.
When availability matters, map which devices depend on this switch and what happens if the primary supply or upstream network fails. Check the backup equipment’s compatibility and electrical capacity as part of the same design. Separate AC backup, DC redundancy and network-path resilience in the plan because they address different failure modes. A powered switch whose uplink or gateway is unavailable may still leave users without connectivity. Ask for the necessary accessories and installation arrangements to be identified explicitly in the quotation.
Rack, temperature and electrical planning
The switch uses a 1U rack-mount chassis with manufacturer dimensions of 442 by 325 by 44 millimetres. The published operating range is minus 5 to 40 degrees Celsius at 10 to 90 percent non-condensing humidity. Electrical input supports 100 to 240V AC at 50/60Hz. Those figures help when choosing cabinet depth, rack placement and environmental management, but they do not excuse ignoring airflow, dust, cable strain or the thermal effects of other equipment in the same enclosure.
Measure available cabinet depth and check clearances for power cords, uplink cables and servicing. Plan cable management so neither the switch nor the patch cords are mechanically stressed. In a warm equipment room, consider the heat generated by the complete rack rather than only this one device. Keep power circuits, protection devices and electrical installation compliant with the requirements applicable to the actual site. For commercial purchasing, confirm whether an appropriate power cable and other mounting accessories are included in the offer.
Tanzania deployment questions worth resolving early
For an organization planning this switch for a Tanzania site, the most useful local considerations are practical ones: the quality of the existing cabling, available electrical protection, ventilation in the communications room, the speed of the installed LAN and WAN, and the ability of the support team to manage UniFi equipment. A business may be upgrading from unmanaged switches, expanding WiFi coverage or consolidating camera power; each situation calls for a different port and energy budget. A technically correct switch can still be a poor purchase if its rack, controller or optics prerequisites are overlooked.
The product’s international technical specifications do not establish local stock, Tanzania-specific licensing or approvals, import terms, price, delivery coverage or warranty arrangements. These commercial and regulatory matters should be confirmed for the exact proposed transaction. If the switch will connect critical business services, include a documented commissioning and recovery plan. Ask the seller to identify the precise model and any required accessories rather than relying on a generic description of a 24-port PoE switch.
A sensible pre-installation checklist
Begin with an equipment inventory and a physical layout. List every endpoint, Ethernet speed, required PoE standard, maximum watts, planned VLAN and cable destination. Check that no more than eight endpoints require the 2.5 GbE interfaces and that no PoE++ endpoint is placed on one of the eight PoE+-only ports. Add the estimated peak loads across the network and compare the result with the shared 400W capacity. Reserve room for expected changes, not just the devices fitted on installation day.
Next, confirm management readiness: the planned UniFi Network instance should meet the stated software requirement and be reachable for adoption and ongoing operation. Document the uplink technology and any transceivers. Check rack fit, cooling, power protection and the optional backup arrangement if relevant. Finally, prepare a change window and decide which business services will be affected when the old network is moved. These checks reduce surprises more effectively than purchasing on headline port count alone.
Commissioning sequence for an orderly cutover
An organized installation begins by verifying the received model and recording equipment identifiers in the asset register. Fit the switch in a suitable rack location, connect the correct power source and establish a management connection in accordance with the chosen topology. Adopt it into a supported UniFi Network environment, review software and firmware compatibility, and apply the approved management, VLAN, uplink and endpoint-port settings. Proceed incrementally so a single incorrect configuration does not disconnect an entire facility.
After connecting the first representative devices, verify negotiated link speeds, VLAN assignment, PoE delivery and upstream reachability. Test at least one device from each major class: wireless access point, security camera, office endpoint and any specialist AV system. Check that traffic reaches the correct destination and that intentional restrictions function as designed. Record the final configuration, physical port labels, controller information and recovery steps. Obtain sign-off against the original equipment schedule before moving the deployment into normal operation.
Troubleshooting link speed, power and reachability
If a device is online but operating at an unexpected rate, start with the physical path: confirm the endpoint capability, port group, patch cable and negotiated speed. A 2.5 GbE device connected to a Gigabit-only interface will not achieve a multi-gigabit link. If an endpoint does not power up, check its required PoE class, port capability and the combined switch power budget. A healthy switch cannot force an incompatible device to accept the wrong standard, nor can it ignore the total wattage limit.
When an endpoint has power and link but cannot reach its services, inspect the VLAN profile, management path, DHCP allocation and routing rules. For a disconnected switch, examine the upstream connection and controller accessibility before attempting disruptive resets. Use port information and Etherlighting as diagnostic aids where supported, then compare the actual configuration with the approved port map. Troubleshooting is much faster when each change and connected endpoint has been recorded.
When a different UniFi switch may be more appropriate
The Pro Max 24 PoE is not automatically the best switch for every site. A small network with few powered devices might not need 24 ports or a 400W budget. A larger network with many multi-gigabit endpoints could need more than eight 2.5 GbE copper connections. A high-density camera installation might exhaust the shared power budget despite having enough available sockets. Another environment may require 10 GbE downlinks to multiple workstations rather than just SFP+ uplinks toward the network core.
Compare candidate models using the number and speed of copper ports, PoE standard on each group, total PoE budget, uplink types, management platform, power-resilience requirements and rack constraints. Check the actual offered specification for any alternative rather than assuming that similar names imply equivalent interfaces. The right decision is the model that satisfies the endpoint and operational requirements with reasonable capacity for growth, not simply the switch with the longest feature list.
What to include in a request for quotation
A useful quotation request should state the exact product model, USW-Pro-Max-24-PoE, and the expected quantity. Add a summary of the current network, the number of powered endpoints, high-power PoE++ requirements, expected multi-gigabit connections, the intended 10G uplink medium and whether the installation needs a compatible backup-power accessory. Mention any project requirements for mounting hardware, optics, patch cables, environmental protection or initial setup support. The clearer the technical schedule, the easier it is to distinguish essential items from optional additions.
Ask for confirmation of current Tanzania availability, pricing in the seller’s applicable terms, scope of supply, warranty conditions and any project-specific procurement requirements. These details are not established by the manufacturer’s generic technical sheet. Where possible, have the final device schedule checked before purchase so that endpoints, VLANs, PoE consumption and the network core are treated as one system.
Verified model specifications
Manufacturer and model
Ubiquiti | USW-Pro-Max-24-PoE
RJ45 interfaces
16 × 1 GbE and 8 × 1/2.5 GbE
PoE classes
8 × PoE+ and 16 × PoE++
Shared PoE availability
400W total
Uplinks
2 × 10G SFP+
Switching performance
112 Gbps switching capacity; 56 Gbps non-blocking throughput
Forwarding
Approx. 83 Mpps
Layer 3
Local inter-VLAN routing, static routing, DHCP functions
Management
UniFi Network 8.0.24 or later
Form factor
1U; 442 × 325 × 44 mm
Status and visual aids
1.3-inch touchscreen and Etherlighting
Power input
100–240V AC, 50/60Hz; optional compatible USP-RPS DC input
These specifications identify the exact hardware model and provide a planning starting point. They do not imply that transceivers, power backup hardware, patch leads, a controller appliance or professional installation services are bundled. Review the final quotation and the most current official model documentation for any configuration-specific needs.
Frequently asked questions
Does the Pro Max 24 PoE have 24 PoE ports?
Yes. It has 24 RJ45 Ethernet ports with PoE capability, divided into eight 1 GbE PoE+ ports, eight 1 GbE PoE++ ports and eight 2.5 GbE PoE++ ports. It also has two 10G SFP+ uplink ports, which are not copper PoE outputs.
How much PoE power can the switch provide?
Its total shared PoE budget is 400W. Each device must fit the power class of its assigned port, and the combined load of connected powered devices must remain within that overall limit. Check peak consumption, not just nominal or idle power.
Are all the Ethernet ports 2.5 GbE?
No. Eight RJ45 ports support speeds up to 2.5 GbE; the other sixteen are Gigabit Ethernet ports. This is an important purchasing consideration when planning a large fleet of newer wireless access points or multi-gigabit endpoint devices.
Can I connect the switch to a 10G backbone?
The switch has two 10G SFP+ interfaces. Connection to a compatible 10G backbone requires an appropriate physical medium, such as a supported transceiver and fiber link or a compatible direct-attach cable. Check interoperability at both ends.
Does it provide local Layer 3 routing?
It supports selected Layer 3 functions, including local inter-VLAN routing, static routing, DHCP relay and local DHCP functions. The final network design still needs appropriate gateway, firewall and routing decisions; the switch is not a general substitute for an internet-edge security appliance.
Which UniFi Network version is required?
Ubiquiti specifies UniFi Network version 8.0.24 or later for the Pro Max 24 PoE. Before deploying it in an existing installation, verify compatibility with the actual controller environment and assess the implications of any required software upgrade.
What does Etherlighting do?
Etherlighting uses illuminated port indicators to help identify connections and visualize relevant status such as port location, link or native network assignment. Ubiquiti recommends compatible Etherlighting patch cables for the intended lighting effect. Maintain physical labels even when using this feature.
Is a redundant power supply included?
The device has a compatible DC backup-power input, but the published capability should not be interpreted as confirmation that an external backup unit is bundled with a particular offer. Confirm compatible accessories and the quotation’s contents before purchasing.
Can I power access points and cameras at the same time?
Yes, where the endpoints use compatible PoE standards, connect to appropriately rated ports and remain within the switch’s total 400W PoE budget. Calculate maximum demand for the complete mix, including high-power or motorized camera features.
Can the switch replace a firewall or video recorder?
No. Its core role is managed Ethernet switching with PoE and supported local network functions. Internet-edge security policy and surveillance recording require appropriate additional systems. Those components should be included in the wider infrastructure design.
Is this suitable for a Tanzania office deployment?
It may be suitable when the office needs its particular mix of PoE+, PoE++, Gigabit, 2.5 GbE and 10G SFP+ uplinks. Suitability depends on equipment demands, electrical conditions, rack environment, existing network compatibility and local commercial confirmation.
What should I confirm before ordering?
Confirm the exact model, number of ports at each required speed, PoE device schedule, 400W budget, uplink cable or optics, supported controller version, rack and power requirements, optional backup accessories and the seller’s current price, availability and warranty terms.
Request a Pro Max 24 PoE quotation for your network
Share your endpoint list, required PoE wattage, number of 2.5 GbE devices, preferred 10G uplink method and installation conditions. Ask for confirmation of the exact USW-Pro-Max-24-PoE model, any required accessories and the current Tanzania offer. A specification-led quote helps ensure the proposed switch fits the project before you place an order.
Contact FourTeck to request details and confirm terms. No local availability, price, coverage or delivery commitment is assumed here.









Reviews
There are no reviews yet.