Ubiquiti Enterprise Audio/Video Fiber (EAV-Fiber)
The Ubiquiti EAV-Fiber is a high-capacity fiber-oriented switch for professional audio and video over IP. It brings 20 × 10G SFP+ connections, 2 × 100G QSFP28 uplinks, hardware-assisted PTP timing and advanced AV traffic controls into a rack-mount platform. The aim is dependable aggregation and synchronization for a properly engineered media network, not simply a faster office LAN.
Quick decision guide
Choose this switch when a project genuinely needs dense 10G optical AV connections, fast uplinks and carefully managed real-time media timing. Before requesting a quote, verify endpoint interfaces, optical distances, PTP requirements, multicast behavior, available rack depth and the separate equipment needed for PoE-powered endpoints. If the project primarily needs copper network ports or ordinary internet access, another model may fit better.
| Specification | Verified details |
|---|---|
| Model | EAV-Fiber (previously named EAV-Aggregation) |
| Switch type | UniFi Enterprise Audio/Video Layer 3 switch |
| Fiber interfaces | 20 × 10G/1G SFP+ |
| High-speed uplinks | 2 × 100G/40G QSFP28 |
| Additional interfaces | 1 × 1GbE RJ45; 1 × serial console; 1 × SMA |
| Performance | 800 Gbps switching capacity; 400 Gbps non-blocking throughput; 595 Mpps forwarding |
| Timing | IEEE 1588-2008 PTPv2; Grandmaster, Boundary and Transparent roles |
| Network features | IGMP controls, Pro AV profiles, QoS, VLANs, selected Layer 3 functions |
| Redundancy | 2 × hot-swappable power modules; 4 × hot-swappable fans |
| Power | 100–240V AC, 50/60Hz; 150W maximum consumption |
| Installation | Full-depth 1U, 19-inch four-post rack |
| Dimensions | 442.4 × 480 × 43.7 mm |
| Environment | −5 to 40°C; 10–90% noncondensing humidity |
| PoE | No PoE output specified |
A fiber-centered switch for professional media transport
The EAV-Fiber addresses a specific infrastructure problem: many professional AV installations need large numbers of reliable high-speed paths into a common switching layer while keeping media streams synchronized. A conventional small office switch may move ordinary business traffic effectively but lack a useful combination of dense 10G optical connectivity, 100G uplinks, advanced multicast controls and PTP timing. The EAV-Fiber combines those capabilities in one UniFi-managed chassis. It is especially relevant when the switching core connects editing rooms, production areas, stage systems or specialist AV endpoints through optical links.
Think of this device as network infrastructure rather than a complete audio or video appliance. It forwards Ethernet frames and supports advanced network configuration; it does not create video content, convert an HDMI signal on its own, or provide analog sound interfaces. The operational value comes from pairing the switch with compatible AV senders, receivers, optical transceivers, media devices, gateways and management arrangements. The right purchasing decision therefore begins with an endpoint and traffic inventory, not just with the largest number printed on the front-panel specification.
Port configuration and what each interface means
Twenty SFP+ slots support 10G or 1G Ethernet according to Ubiquiti’s specification. These ports are designed for supported optical modules or suitable direct-attach connectivity, rather than direct insertion of an ordinary copper Ethernet plug. The two QSFP28 interfaces support 100G or 40G operation and are natural candidates for high-capacity uplinks to another switching tier. There is also one 10/100/1000 Ethernet RJ45 interface, a separate serial console interface and an SMA connector associated with optional external timing. Each interface serves a different function in a planned AV network.
Do not count a 10G SFP+ slot as a 10G connection until the selected transceiver, cable, remote device and actual link negotiation support that speed. Likewise, a 100G QSFP28 uplink is not an automatic promise of 100G application throughput to every source. Link capacity must be shared among flows, and traffic patterns may converge on fewer paths. List every endpoint, speed, optic, cable type, distance and resilience requirement, then map it to a specific port before committing to the chassis.
Understanding 800 Gbps switching capacity
Ubiquiti lists 800 Gbps switching capacity, 400 Gbps total non-blocking throughput and a forwarding rate of 595 million packets per second. These measurements describe different aspects of the switching platform; they should not be added together or interpreted as one application’s guaranteed data rate. The switching-capacity figure expresses the fabric’s overall internal switching capability, whereas the non-blocking-throughput specification is the more direct headline for aggregate one-directional traffic capability across the available interfaces.
For AV design, the essential question is still whether traffic can travel through the intended paths without oversubscription or excessive queuing. A large number of compressed monitoring streams may present very different demands from several uncompressed broadcast-video feeds. Packet sizes, burst behavior, source-to-destination fan-out and other data sharing the switch all influence the result. Estimate the bandwidth of each actual media format, reserve a sensible engineering margin and review what will happen when several productions run at once.
Choosing and sizing the 100G uplink paths
The two QSFP28 ports allow the switch to connect high-bandwidth access or aggregation links into a wider media network. In a suitable topology, a 100G uplink can carry traffic from multiple lower-speed SFP+ devices toward a core or another AV segment. The ports also support 40G operation, which may be important when connecting to older infrastructure. Actual interoperability depends on the transceiver or cable and the remote interface, so the intended peer must be checked rather than assumed.
Build a simple traffic matrix with sources on one side and destinations on the other. A camera feeding many receiving devices, a central vision processor handling multiple streams, and a recording server with concentrated ingest can create very different uplink loads. Where paths are redundant, consider how much traffic the remaining route would carry after a single failure. Do not assume that two 100G ports double the useful capacity of a particular single flow, especially where hashing, endpoint behavior or PTP timing constraints apply.
Optical modules, DAC cables and link distances
Buying a fiber-oriented switch also means planning the physical media. Short rack-to-rack connections may be candidates for compatible direct-attach cables; links through a building may call for multimode or single-mode fiber and matched optical modules. The correct choice depends on distance, existing fiber type, connector and patch-panel arrangement, permitted optical budget and equipment compatibility. The EAV-Fiber chassis alone does not answer these questions. Confirm the available accessories and the bill of materials for each link.
For every proposed optical run, record the origin, destination, fiber type, number of strands, connector presentation, length, expected link rate and spare capacity. Check that both ends use a compatible optical standard and that transceiver wavelengths and receive power ranges match. Allow for patch panels, joints and practical service loops. Optical link verification is a commissioning task, not a box-ticking exercise; correct module selection and cleanliness can prevent faults that otherwise appear to be mysterious AV or timing instability.
Why Precision Time Protocol matters to AV
Professional digital audio and broadcast video often involve many devices that must agree on time much more closely than typical office computers. Ubiquiti specifies IEEE 1588-2008 PTPv2, with hardware timestamping on the switch’s Ethernet and QSFP28 ports. The device also uses a high-precision OCXO clock. These features make the EAV-Fiber a useful component when the chosen media ecosystem needs accurate timing, for example in supported AES67 and SMPTE ST 2110 environments.
PTP is a timing system, not a replacement for throughput planning or proper multicast configuration. A network may have excellent bandwidth yet suffer from media glitches if its clocks, profiles and forwarding paths are inconsistent. Conversely, correct PTP operation cannot compensate for congested links or unsuitable encoders. Design the timing domain as deliberately as the data network. Identify the clock source, expected roles, timing transport and the devices that must share synchronization before deciding where the EAV-Fiber should sit.
Grandmaster, boundary and transparent clock roles
Ubiquiti documents Grandmaster, Boundary and Transparent clock modes for its Enterprise AV switches. A Grandmaster supplies reference timing for a PTP domain; for a GPS-referenced arrangement, Ubiquiti describes an external GPS clock connected through the SMA port. A Boundary clock follows upstream timing and distributes it to downstream devices. A Transparent clock forwards PTP messages while compensating for the time spent within the switch. The choice should reflect the intended topology and the roles already performed by other equipment.
Ubiquiti indicates that Transparent is the default setting and that the design should provide a suitable primary Grandmaster. It also notes that Boundary clock operation is two-step only. Do not casually introduce multiple unmanaged timing masters or assume a GNSS antenna is included with the switch. Document how the network chooses its master and how it behaves after a timing-source failure. In more complicated AV installations, use the relevant manufacturer’s clocking guidance for every connected endpoint rather than relying on a switch preset alone.
PTP profiles and interoperability planning
The EAV-Fiber supports PTP profiles including IEEE 1588, SMPTE 2059-2, AES67 and AES-R16, with configurable timing intervals, domain number and priority values. The correct profile depends on the devices and transport standards in use. SMPTE 2059-2 is relevant to appropriate broadcast workflows, while AES67 timing applies to compatible networked-audio systems. Mixing profiles or timing expectations without a deliberate integration design can cause inconsistent lock, audio errors or intermittent behavior.
During specification, note which device is the timing leader, which domain number is expected, whether each device uses Layer 2 Ethernet or UDP/IPv4 PTP transport, and whether the required delay mechanism is supported. Ubiquiti specifies end-to-end delay and documents several custom profile controls. Its guidance also says PTP operates on the native VLAN and does not support link aggregation. Treat those points as real topology constraints when drawing redundant paths and planning how AV traffic crosses trunks.
Multicast, IGMP and stream distribution
Many AV-over-IP workflows transmit multicast data, allowing one source to serve multiple subscribed receivers. Without careful forwarding rules, multicast traffic can reach ports that do not need it, consuming bandwidth and sometimes disturbing unrelated equipment. The EAV-Fiber offers IGMP snooping and advanced IGMP controls including querier, Fast Leave and router-port settings. Those controls are useful only when applied consistently across the relevant VLANs and switching path.
Ubiquiti recommends IGMP snooping and a clearly designated querier for the relevant media environment. The exact Fast Leave setting may differ among Dante, Q-SYS, AES67, NDI and SDVoE designs, especially if multiple receivers share a physical access port. The treatment of unknown multicast groups and known PTP protocols also needs attention. Test joining and leaving streams while monitoring switch port usage. A successful unicast ping does not prove that AV multicast distribution is configured correctly.
Pro AV profiles and traffic prioritization
UniFi provides Pro AV optimization profiles for environments such as Dante, Q-SYS, NDI, SDVoE, Shure, AES67, Crestron and its own Play-related workflow. These profiles can match relevant traffic and apply quality-of-service prioritization. Ubiquiti’s guidance explains that matching can use DSCP and CoS values along with protocols and ports. This offers a structured starting point for a mixed control, media and enterprise network, rather than requiring every traffic class to be built from scratch.
Profiles are not a blanket guarantee that a third-party device is certified or will operate with every feature enabled. Match the exact endpoint behavior and installed software versions. Ubiquiti further advises applying suitable QoS handling on every port that carries the media, including switch-to-switch trunks, not just on the source-facing access port. Create a simple traffic-class plan for timing, real-time media, control and ordinary applications, then verify it in a live stream test.
VLAN planning for audio, video and control
Segmenting networks can make professional AV easier to operate and troubleshoot. A venue may separate media streams, management interfaces, show-control systems, guest traffic and general business devices into appropriate VLANs. The EAV-Fiber supports up to 1,000 VLANs, but the number alone is not a reason to create unnecessary segmentation. Every additional network boundary must fit the actual discovery, multicast and routing needs of the devices attached to it.
Before implementation, ask which devices must discover one another automatically, which need Layer 3 reachability, and which send timing or multicast traffic that should remain within a particular domain. Ubiquiti’s PTP guidance identifies native-VLAN behavior that must be considered when creating trunks. An otherwise sensible segmentation design can block device discovery or misroute timing. Record port membership, tagged versus untagged expectations and exception paths in a reusable network diagram, then validate each class of traffic separately.
Layer 3 functions and routing boundaries
Although the EAV-Fiber is promoted for professional AV, it also includes selected Layer 3 functions such as DHCP service for local networks, DHCP relay, inter-VLAN routing for local networks and static routing. Ubiquiti lists support for 512 IPv4 static routes. These functions can simplify certain localized designs, but they do not mean that the switch should replace every router, firewall, WAN gateway or security policy system in a larger installation.
Place routing boundaries where the application requirements and support model make sense. It can be tempting to route every control and media subnet centrally, yet some AV systems assume a common broadcast or multicast domain, while others explicitly support routed operation. Review the vendor’s topology rules, TTL expectations and device-discovery method. Keep internet security, policy enforcement and site-to-site connectivity within appropriately designed infrastructure. The primary value of this product remains high-capacity switched media transport with AV-aware controls.
Security controls for an AV production network
An AV network is still an enterprise network. The EAV-Fiber offers features including 802.1X, MAC-based access controls, IP-based ACLs, DHCP snooping, port isolation, rate limits, storm control and port mirroring. Those features can help organize access, reduce accidental exposure and investigate faults when properly configured. They do not eliminate the need for sound credentials, software maintenance, physical protection, asset records and an appropriate security boundary to external networks.
Separate operational security from signal continuity. Blocking an unfamiliar port may be desirable on a corporate user network but disruptive if a show-critical endpoint suddenly needs to authenticate or exchange multicast control packets. Test policies in a staging environment and document any required exceptions. Avoid assuming all devices implement 802.1X identically. For production use, maintain configuration backups, a controlled change process and clear ownership of the network during rehearsals, live events or other critical service windows.
Redundant power and hot-swappable cooling
The chassis includes two hot-swappable 150W AC/DC power modules and four hot-swappable fan modules. Ubiquiti specifies 100–240V AC, 50/60 Hz input and a maximum power consumption of 150W. This arrangement is valuable in a media rack where unnecessary shutdowns can interrupt many connected endpoints. Hot-swappable components also support more practical field maintenance than a sealed unit with no replaceable power or fan modules.
Redundancy is strongest when the wider installation supports it. Review whether independent power feeds, suitable protection and a correctly rated UPS are available, and avoid putting both power inputs behind the same fragile extension cord. Verify replacement-module availability through a suitable supply channel. Power modules do not make the whole network fault tolerant: upstream switches, fiber routes, attached devices, synchronization sources and management systems may still be single points of failure. A realistic resiliency design considers each of those dependencies.
Rack depth, airflow and environmental limits
The EAV-Fiber occupies 1U but is a full-depth chassis measuring approximately 442.4 × 480 × 43.7 mm. Ubiquiti specifies use with 19-inch four-post racks having post depths from 650 to 1,000 mm. For a two-post rack, its product guidance recommends appropriate center-mount or cantilever support. The weight is approximately 8.95 kg without mounting brackets, so mechanical support and cable management deserve attention during planning.
Check the clearance behind the rack, bend radius of optical patch cables, power-cord access, air movement and usable rack depth before ordering. Operating temperature is specified from −5°C to 40°C, and relative humidity from 10% to 90% noncondensing. In a warm equipment room, evaluate heat output and cooling rather than assuming the ambient environment is automatically acceptable. Ubiquiti lists heat dissipation of 512 BTU/hr. For sites with dust, heat fluctuation or unstable power, environmental conditioning and maintenance may matter as much as the switch’s feature set.
The local screen, Etherlighting and visibility
A 1.3-inch touchscreen gives onsite personnel a convenient local interface for viewing device information. Ubiquiti also includes Etherlighting on SFP+ and QSFP28 interfaces. Together with the UniFi management environment, these features may make it easier to identify a link, trace a connection or check the state of equipment during service. They are helpful operational aids, especially in densely populated racks where similar optical jumpers can be easy to confuse.
Monitoring still requires an organized process. Label fiber terminations at both ends, record actual transceiver types and maintain a port schedule in the project’s documentation. Establish alerts or review routines suitable for link health, device reachability and power issues in the chosen management stack. A status light is not a substitute for measuring packet loss, interface errors, clock stability or multicast behavior under load. Keep an up-to-date baseline so the support team can distinguish a normal traffic increase from a developing fault.
Planning a broadcast or studio workflow
A studio may combine media processors, audio consoles, video equipment, monitoring endpoints and networked recording systems on a common switched infrastructure. For compatible SMPTE ST 2110 workflows, accurate PTP timing and adequate bandwidth are central considerations. The EAV-Fiber brings high-speed optical connections, large uplinks and hardware-aware timing options together, making it a potential aggregation component in such a design. Its practical suitability still depends on stream formats and the entire equipment chain.
Start with the real production graph: which camera or processor feeds which destinations, how many simultaneous streams run, and whether timing and control flows use the same paths. Model the highest expected ingress and egress loads, including recordings and multiviewers. Determine which clocks must lock together and how they recover after a failure. Before live deployment, rehearse a complex switching or recovery event with all intended sources active. This is the kind of test that reveals capacity and network-configuration issues earlier than a simple idle-state demonstration.
Live events, performance venues and stages
In a performance venue, fiber may connect stage racks, front-of-house positions, recording areas and centralized equipment rooms. Distance, electrical isolation requirements, physical routing and high-channel-count media transport can make optical Ethernet attractive. EAV-Fiber can serve as part of the distribution layer where multiple 10G paths meet, especially when uplinks must carry concentrated AV traffic. The network design should still match the audio and video systems already selected for the venue.
Live venues add practical risks not always present in an office: temporary patching, rapid setup changes, equipment arriving from outside vendors and limited windows for testing. Create a labeled patch plan, identify authorized optic types, reserve spare cables and make sure timing and IGMP responsibilities are explicit. Run a repeatable pre-show checklist, including synchronization status, multicast join behavior and trunk utilization. Avoid applying software updates or untested traffic policies immediately before a production without an established change and rollback plan.
Auditoriums, campuses and distributed AV
A large auditorium or education campus can have lecture capture, digital signage, streaming endpoints, room-control systems and production rooms connected across separate network closets. A fiber-rich central switch may be more appropriate at aggregation than at an individual desktop or classroom. The EAV-Fiber’s large uplinks can help gather such connections, provided the wider network and the chosen endpoints support the desired architecture and the links are sized for simultaneous activity.
First separate two requirements that are often confused: long-distance inter-building transport and real-time AV synchronization. Fiber type, optical loss, route resilience and physical pathway rules dominate the first problem. PTP, multicast, QoS and media-format requirements dominate the second. Some campus applications may be conventional video streaming and not need the advanced timing features at all. In that case, compare the overall solution cost with a simpler aggregation switch rather than paying for specialized capabilities that the project does not use.
Enterprise meeting facilities and production suites
High-end meeting facilities may distribute presentations, digital signage, production feeds and audio across many rooms. Depending on the selected endpoint ecosystem, these systems can benefit from reliable multicast forwarding, consistent traffic prioritization and an organized central network. The EAV-Fiber is a candidate where high-speed optical density and advanced timing are relevant, rather than an automatic requirement for every boardroom. Many smaller facilities function well with ordinary access switches.
When evaluating this use case, ask how many endpoints really require 10G links, which are powered by PoE, and whether any audiovisual devices use standard copper RJ45 networking. Plan the complementary access layer accordingly. The EAV-Fiber does not provide PoE output on its SFP+ or QSFP28 interfaces, so PoE-powered endpoints need an appropriate switch or power arrangement elsewhere. Distinguish the fiber aggregation purchase from the endpoint access purchase so the proposed bill of materials remains complete.
A practical bandwidth-estimation method
Rather than guessing capacity from a marketing label, calculate the likely offered load. Record each media feed’s nominal bit rate, count simultaneous instances and identify where multicast is duplicated or switched. Add control traffic, management traffic and the required headroom for burst behavior. Next draw the physical route each important stream follows. If eight high-rate sources converge on a single uplink, that uplink must be evaluated against their combined real traffic, not against the theoretical capacity of the entire chassis.
Use manufacturer or codec documentation to obtain actual stream rates; do not infer bit rate solely from terms such as 4K, 60 frames per second or uncompressed. The use of compression, bit depth, color sampling, transport encapsulation and application overhead changes the result dramatically. Record expected and worst-case cases for rehearsal, live production and recording. Where the design approaches a port’s usable limit, revise the topology or media profile instead of assuming QoS can manufacture missing bandwidth.
Commissioning sequence for a new installation
Begin with a documented physical inventory, correct rack mounting, properly protected power and the optical modules selected for the actual links. Adopt the switch into the appropriate UniFi management environment using the organization’s approved process, then record software and firmware versions. Ubiquiti’s Pro AV guidance lists UniFi Network 8.4.59 or later and switch version 7.1.26 or later as baseline requirements for the cited feature family; feature-level requirements can differ, so verify current release compatibility before configuration.
Next create and document VLAN and port profiles, confirm correct link negotiation and basic unicast reachability, then configure the required AV profiles, QoS and multicast controls. Establish the timing source and clock roles before asking the audio or video system to lock. Verify IGMP join and leave behavior, monitor stream delivery and watch interface counters under the intended production load. Finally test one relevant fault or cable interruption, save the approved configuration and hand over a topology diagram and recovery checklist.
Common misconfigurations to avoid
One frequent mistake is assuming that a profile on a source-facing port automatically prioritizes traffic across the entire path. Ubiquiti states that suitable QoS handling also needs to cover trunks and other ports carrying that media. Another is enabling multicast snooping without making sure a querier exists where required. Yet another is treating all traffic as routable when a chosen AV ecosystem depends on a particular Layer 2 discovery or timing behavior. Those faults can produce intermittent symptoms that resemble defective hardware.
A fourth mistake is placing PTP traffic across an unsupported aggregation arrangement. Ubiquiti explicitly states that its PTP configuration does not support link aggregation and that PTP operates on the native VLAN. Also avoid casual assumptions about unmanaged optical modules, questionable patch cords and mixed timing profiles. When a system misbehaves, troubleshoot systematically: physical errors first, correct VLAN and routes second, timing third, multicast behavior fourth and application-specific settings after that. Record the exact test result for each stage.
What this product does not replace
The EAV-Fiber is not an HDMI capture card, video encoder, digital audio processor, firewall, or general-purpose PoE access switch. Its core product role is high-bandwidth Ethernet switching with specialized professional AV functions. Buying it does not include an end-to-end production system, remote camera, recorder or audio console. Such components must be selected and priced separately based on the intended workflow and supported protocols.
It is also not automatically the right choice for every office requiring faster fiber. Where a project needs mostly 1G RJ45 copper ports or PoE-powered endpoints, a more conventional access switch may be the better primary device. Conversely, a large ST 2110 or AES67 deployment can demand more careful timing engineering than an ordinary enterprise network upgrade. Explain the need for precise clocks and high-speed optical aggregation in the design brief. If those needs are absent, compare alternative switch architectures before choosing.
Tanzania project planning considerations
For buyers planning professional AV infrastructure in Tanzania, early project questions should include where the equipment will be installed, what fiber infrastructure already exists, whether the rack room has suitable cooling and how the site will manage power quality. These are design considerations, not claims that a particular local supply or installation service is available. A high-density media switch can be a major dependency for production, so the operational surroundings should be evaluated alongside the published specification.
Ask for a quote that separates the switch, supported optics, DAC or fiber patching, rack accessories, power arrangements and any professional configuration work the project needs. Confirm voltage and connector details for the actual supplied regional unit, and have the supplier verify applicable commercial terms, logistics and support arrangements in writing. No Tanzania-specific selling price, delivery promise, stock statement or local approval is asserted here. Those matters require confirmation for the actual offer.
Questions to resolve before requesting a quote
A useful request for quotation includes the total count of 10G and 100G links, physical locations, optical media and distances, the intended audio and video technologies, the required PTP clock strategy, and the number of simultaneous streams. State whether a management system already exists and whether the EAV-Fiber will be a core, distribution or edge component. Provide the rack depth and power details because those determine mechanical and electrical readiness.
Also identify the service objective: is the application a permanent broadcast facility, a portable event system, a teaching venue or a mixed corporate AV network? Note any shutdown restrictions, redundant-path requirements and test acceptance criteria. This information lets an integrator produce a more complete design and bill of materials, not just a chassis-only price. It also helps identify when another class of switch, additional PoE access equipment, a separate timing source or endpoint conversion hardware is necessary.
Evaluating lifecycle, maintenance and support
Operational readiness begins before installation. Decide who owns the UniFi management account, who may change network policies and who can inspect switch health during a production. Track deployed software versions and relevant Ubiquiti advisories. Keep a safe record of configuration, labeled links and timing settings, and arrange maintenance windows around the media schedule. Availability of replacement power or fan modules, local parts logistics and contractual response terms should be confirmed with the supplier rather than assumed.
Plan for growth carefully: future endpoints might add new media formats, higher stream counts or additional optical connections. Record currently unused ports, uplink margins and fiber spares to show whether the design has real expansion space. A platform with impressive headline bandwidth can still run out of suitable ports or exhaust a specific transport path. Reassess the traffic matrix and interconnection strategy after a meaningful expansion, and verify new devices in a controlled staging test before connecting them to a live AV timing domain.
Frequently asked questions
Is the Ubiquiti EAV-Fiber a normal 10G switch?
It can switch ordinary Ethernet traffic, but its focus is professional AV aggregation. Twenty 10G/1G SFP+ interfaces, two 100G/40G QSFP28 ports and specialized timing and multicast features make it different from a typical copper access switch. Select it because those capabilities fit the media design, not merely because the name includes Enterprise.
How many 100G uplinks does it provide?
There are two QSFP28 interfaces, each specified for 100G or 40G operation. Their usefulness depends on compatible remote equipment and the selected optical or direct-attach connection. Two ports do not by themselves guarantee that a single traffic flow can use their combined capacity.
Does the EAV-Fiber supply PoE power?
No PoE output is specified for its fiber-oriented SFP+ and QSFP28 ports. Devices that need PoE, such as some AV transceivers or control devices, require an appropriate separate PoE-capable access switch or other supported power arrangement. Include that equipment in the full project budget.
Can the switch support Dante or AES67 audio?
Ubiquiti lists Pro AV profiles including Dante and AES67, and the switch supports suitable PTP features for professional audio synchronization. Successful deployment still depends on endpoint behavior, timing profiles, QoS, multicast configuration and overall design. A traffic profile should not be interpreted as universal product certification for every third-party feature.
What is the purpose of the SMA connector?
The SMA interface is associated with an optional external GPS-referenced timing source for PTP Grandmaster operation. It is not a normal Ethernet data port. Confirm the supported antenna or timing arrangement, relevant accessories and the actual supplied kit when choosing a GPS-referenced clock design.
Is a four-post rack necessary?
Ubiquiti specifies a full-depth 1U switch and identifies 19-inch four-post racks with 650–1,000 mm post depth. The manufacturer advises proper center-mount or cantilever support for two-post setups. Verify rack structure, airflow, cable clearance and load support before installation.
What is the difference between switching capacity and useful AV throughput?
Switching capacity describes an internal fabric rating, while the listed non-blocking throughput gives a separate aggregate traffic measure. Neither is a guaranteed application bit rate. Useful stream performance depends on port speeds, traffic concentration, packet behavior, link oversubscription, multicast distribution and the capacity of the endpoints.
Can the EAV-Fiber work as a PTP Grandmaster?
Yes, Ubiquiti documents Grandmaster, Boundary and Transparent timing roles. An appropriately configured external GPS clock can provide a reference for Grandmaster operation. A design also needs consistent PTP profiles, domain settings and appropriate downstream clocks. The default Transparent role assumes that another clock source exists.
Can we use a link aggregation group for PTP?
Ubiquiti’s Enterprise AV PTP guidance specifically says that PTP does not support link aggregation. Design timing paths accordingly instead of assuming that ordinary data-plane LAG support guarantees suitable timing behavior. Record the supported physical paths when drawing redundant links.
Which fiber optic modules should be purchased?
Choose modules according to the optical standard supported at both ends, actual distance, fiber type, connector, wavelength and link rate. Single-mode, multimode and DAC options solve different problems. Confirm transceiver compatibility and whether modules are included in the quote; do not infer a full optical kit from the presence of SFP+ or QSFP28 slots.
Can one switch run office and AV traffic together?
That may be possible when the combined design meets bandwidth, segmentation, security, QoS and multicast requirements. However, critical live media should not depend on unmanaged contention with ordinary traffic. A traffic matrix and risk assessment can indicate whether shared infrastructure is acceptable or dedicated AV switching is preferable.
How can a Tanzania buyer request the right configuration?
Provide a port schedule, proposed fiber distances, AV endpoint list, selected transport standards, required timing source, rack details and any redundancy or commissioning needs. Ask FourTeck Tanzania for a quotation that confirms the exact supplied model, relevant accessories and applicable commercial terms, rather than assuming price or local availability from a product specification.
Request an EAV-Fiber quotation for your project
Share your optical port count, distances, AV endpoint list, selected media standards, PTP clock requirements, rack configuration and expected stream loads with FourTeck Tanzania. Ask for confirmation of the exact hardware offering, compatible modules, separately required accessories, product availability and applicable commercial terms. A complete quotation should reflect the intended network architecture rather than the switch alone.






Reviews
There are no reviews yet.