Ubiquiti UISP Switch Pro UISP-S-Pro

The Ubiquiti UISP Switch Pro (UISP-S-Pro) is a managed aggregation switch intended for networks that need twenty-four Gigabit copper connections, sixteen ports with 27V passive PoE, and four 1/10G SFP+ fiber uplinks. With a 220W shared passive-PoE budget, it can suit compatible wireless internet service provider equipment and distribution sites. Confirm your device voltage and pinout before connecting powered endpoints. For a Tanzania deployment, ask FourTeck Tanzania for a model-specific quotation and describe the connected equipment, uplinks and installation environment. The key purchasing distinction is passive power rather than universal IEEE active PoE: connected radios or other endpoints must explicitly accept the specified 27V output and wiring mode. Each powered port is limited to 30W, and all powered ports share the 220W total. Eight of the copper ports are data-only, making a careful port allocation plan important. SFP+ optics and upstream connection requirements should be checked separately. UISP management compatibility, power continuity, cabinet ventilation and surge protection also deserve attention. No Tanzania price, stock availability, local warranty term or delivery commitment is assumed. Share a device list and project scope to confirm fit before ordering.

Category:

Provider network switching

Ubiquiti UISP Switch Pro (UISP-S-Pro)

The Ubiquiti UISP Switch Pro (UISP-S-Pro) is a managed aggregation switch intended for networks that need twenty-four Gigabit copper connections, sixteen ports with 27V passive PoE, and four 1/10G SFP+ fiber uplinks. With a 220W shared passive-PoE budget, it can suit compatible wireless internet service provider equipment and distribution sites. Confirm your device voltage and pinout before connecting powered endpoints. For a Tanzania deployment, ask FourTeck Tanzania for a model-specific quotation and describe the connected equipment, uplinks and installation environment.

24 × GbE RJ4516 × 27V passive PoE4 × 1/10G SFP+220W total PoE

At-a-glance technical specifications

Model UISP-S-Pro
Copper ports 24 × Gigabit RJ45
Passive-powered copper ports 16 × 27V passive PoE (ports 1–16)
Non-powered copper ports 8 × Gigabit RJ45
Fiber interfaces 4 × 1/10G SFP+
PoE budget 220W shared
PoE per-port maximum 30W at 27V
Total non-blocking throughput 64 Gbps
Switching capacity 128 Gbps
Forwarding rate 95.23 Mpps
Management UISP application 1.5.7 and later; Ethernet in-band and Bluetooth
Power inputs 100–240V AC; 27V DC Power TransPort
Power consumption 30W maximum excluding PoE output
Display 1.3-inch touchscreen
Dimensions 442.4 × 267.5 × 43.7 mm
Weight 4 kg
Operating temperature −10°C to 50°C

Technical values are manufacturer specifications. A project design must additionally verify firmware, powered-device compatibility, cabling, optics and installation conditions.

Choosing a switch for an ISP access site

A wireless internet service provider often needs to aggregate many copper connections at a single cabinet or equipment rack while preserving an upgrade path for the upstream network. The UISP Switch Pro addresses this situation with twenty-four Gigabit Ethernet RJ45 connections, sixteen of which can supply compatible equipment with 27V passive PoE. Four additional SFP+ interfaces accept supported 1G or 10G connections. This combination can reduce the need to position a separate Ethernet switch and multiple individually powered passive-PoE injectors at the same aggregation point. It is especially relevant when network planning includes several radios, customer distribution links, monitoring endpoints or other devices that are explicitly approved for this power type. The result should still be designed around actual site loads, available uplink capacity and the physical location of each connected endpoint.

The decision starts with an inventory rather than a port count alone. Record every device model, its exact input-voltage range, whether it expects passive PoE, the supported wiring mode, maximum consumption and its traffic requirement. Mark ports needed today and ports reserved for realistic expansion. Where devices need 48V passive PoE, IEEE 802.3af/at negotiation or more power than the per-port limit, plan a suitable independent power source or another switch. This avoids the common mistake of assuming that any RJ45 connector labelled PoE can power every type of PoE device. A short compatibility review before purchasing may be more valuable than comparing price tags without examining the power architecture.

Port layout and what the numbers mean

The twenty-four copper LAN ports operate at Gigabit Ethernet speed. They are useful for access connections, distribution to adjacent equipment, management segments and other compatible Ethernet endpoints. Only ports one through sixteen have the specified 27V passive-PoE output capability; the other eight copper ports are data-only for this purpose. That distinction matters during cable labelling and cabinet installation. An engineer should reserve powered ports for devices known to accept that power and use the remaining data ports for connections that are independently powered. Documenting which ports provide power also reduces the chance of attaching an incompatible device during later troubleshooting or equipment replacement.

The four SFP+ sockets add an important transport option. The manufacturer lists them as 1/10G interfaces, which means the project can plan suitable supported transceivers and fiber or direct-attach media according to topology and distance. A 10G-capable uplink does not automatically make every attached customer link faster than 1 Gbps; it provides aggregate upstream capacity when the rest of the path supports it. Network engineers should check optics compatibility, fiber type, distance, connector details and upstream switch settings separately. The total switching capacity specification also does not replace a complete evaluation of congestion, multicast requirements, latency, quality-of-service policy and network management features.

27V passive PoE: the critical compatibility check

The UISP-S-Pro provides 27V passive power, not a universal IEEE 802.3af, 802.3at or 802.3bt power service. Passive PoE can place voltage on specified conductors without the same device-detection and negotiation process used by standards-based active PoE. Ubiquiti specifies two-pair and four-pair wiring arrangements for the powered copper ports. Before a technician enables a powered connection, the destination model must be checked against current manufacturer documentation for both voltage and pin configuration. Matching the product family name alone is not enough, because hardware generations and power requirements can differ. This is particularly important when an installation includes equipment bought at different times or sourced from several vendors.

Incorrect assumptions may cause a connected device to fail to start or potentially damage incompatible hardware. Do not attach ordinary unverified Ethernet equipment to an active passive-PoE output simply because the RJ45 connector fits. Likewise, a radio that requires 24V passive power should not automatically be treated as compatible with 27V; the device’s permitted input range determines suitability. A 48V device and an 802.3at-only device need their own verified solution. Cable pin mapping, surge-protection arrangement and any intermediate patching equipment must be considered along with the voltage. When requirements are unclear, keep power disabled and obtain the exact model’s electrical specification before proceeding.

Understanding the 220W shared power budget

The published total PoE allowance is 220 watts, and the published per-port maximum is 30 watts at 27V. These are different limitations and both must be respected. Sixteen ports cannot each draw the full thirty watts simultaneously because that would exceed the aggregate allowance. A preliminary worksheet should include each connected endpoint’s maximum expected draw rather than relying solely on its idle consumption. Sum the loads across all powered ports, check the 220W total and verify that no single port exceeds its individual limit. An additional operational margin can help accommodate start-up conditions, future accessories and revisions to site hardware, although that margin is a project-design choice rather than an additional guaranteed capacity from the manufacturer.

For example, a proposed installation with eight devices specified at fifteen watts each has a nominal combined demand of 120 watts. That simple arithmetic is not a compatibility approval: the installer must still verify the individual devices’ 27V input requirements, pinouts, cable conditions and actual worst-case demand. If a ninth device is added, recalculate instead of assuming it will fit. Where a cabinet hosts radios with varied peak loads, create a per-port schedule that identifies the owner, device, cable, expected wattage and allowable replacement model. This makes upgrades and maintenance safer than relying on a single site-wide estimate.

10G fiber uplinks and aggregation planning

Four 1/10G SFP+ interfaces allow the switch to participate in a fiber-based aggregation design while retaining copper access connectivity. A WISP can use an appropriate uplink to connect a distribution cabinet to upstream routing or switching equipment, subject to transceiver, media and distance compatibility. The switch’s fiber interfaces are valuable when multiple Gigabit access ports share an upstream path, but performance depends on traffic patterns and on the entire routed or switched path. A design with many active customers still requires realistic oversubscription calculations and enough bandwidth upstream. Port speed is just one part of the service-capacity equation.

Before ordering optics, identify whether the link uses single-mode or multimode fiber, the number of strands available, required reach, connector type and the capabilities of the other endpoint. Verify that both sides accept the intended speed and optical standard. If the fiber run traverses separate buildings or exposed routes, include appropriate physical protection and installation practice. The presence of four SFP+ sockets should not be interpreted as a promise that every third-party module is supported. For critical provider infrastructure, test the chosen optical modules and actual link behavior before scheduling a customer-impacting migration.

Switching performance specifications in context

Ubiquiti publishes 64 Gbps of total non-blocking throughput, 128 Gbps switching capacity and a forwarding-rate figure of 95.23 million packets per second. These figures describe different aspects of the switching platform and must not be added together or presented as a guaranteed internet speed. A copper client connected at one Gigabit cannot obtain a ten-Gigabit physical link simply because the chassis has high aggregate capacity. Similarly, a 10G uplink can be constrained by upstream routing, optical equipment, traffic policy, protocol overhead or congestion elsewhere in the service chain. Interpreting the specifications correctly helps set realistic procurement expectations.

For operational planning, estimate the peak and sustained traffic presented by each port group, the likely mix of packet sizes and the upstream path used by those flows. Consider whether a topology needs separate redundancy arrangements, additional aggregation points or a faster router. Do not infer a specific Layer 3 feature, routing protocol, security function or service-level guarantee from the switching capacity alone. Those capabilities should be confirmed in the firmware and management documentation relevant to the actual deployment. A clear topology diagram and acceptance test will do more to prove site readiness than repeating a headline throughput number.

Management with UISP

The manufacturer’s technical specification identifies UISP management support from application version 1.5.7 onward. UISP is intended for operators managing provider infrastructure, making it a natural management context for this device. The switch also lists in-band Ethernet and Bluetooth management interfaces. The local touchscreen provides an additional on-device interface for suitable status and setup interactions. These interfaces can make deployment and equipment identification more convenient, but they do not eliminate the need for a secure management design or trained staff. Check the currently supported controller and firmware combination before integrating the unit with an existing UISP installation.

An operational design should record the management IP scheme, administrative responsibilities, credentials policy, approved firmware procedure and expected monitoring workflow. Plan how to reach the site when the normal customer-facing uplink is unavailable. Keep backup configuration procedures and device labels consistent across locations. Where a team also uses UniFi products, avoid assuming that UISP switches appear in UniFi Network as native UniFi-managed switches; the management ecosystems and intended workflows are distinct. Confirm integration requirements before promising a single controller for a mixed environment. Document what the chosen UISP release actually supports rather than advertising unverified features.

Installation footprint and rack preparation

The switch measures 442.4 by 267.5 by 43.7 millimetres and weighs approximately four kilograms according to Ubiquiti’s published specifications. The dimensions suit the planning of a rack-based installation, but cabinet depth, rails, connector clearance and ventilation should be checked against the actual location. Leave enough room for fiber patch cords to follow a sensible bend radius and for copper cables to be dressed without obstructing other equipment. A neat rack front is useful, yet the rear space for power routing and airflow is equally important. Confirm mounting accessories and the installation procedure against the manufacturer’s current installation guide for the exact model.

For sites with frequent maintenance activity, use clear port labels, a patching schedule and cable routing that allows a failed component to be replaced without disturbing unrelated circuits. Mount the switch so that its touchscreen and indicators can be accessed by authorized technicians. Consider equipment weight, rack stability and the sequence of installation before placing the device in a crowded enclosure. The product’s specified operating range is not an instruction to ignore airflow or local enclosure temperatures. Heat from surrounding power supplies, radios, batteries and UPS units can affect the actual environment inside a cabinet.

AC and DC power input planning

Ubiquiti specifies a universal AC input of 100–240 volts, 50/60Hz, alongside a 27V DC Power TransPort input rated at 9.3 amps. The listed internal AC/DC supply is 250 watts. These inputs provide deployment-planning options, but installers should follow the official wiring guidance instead of treating them as a general promise of automatic redundancy, hot-swap capability or uninterrupted changeover. Confirm what accessory, cabling and integration are needed for the chosen DC arrangement. For a conventional AC-powered rack, ensure the available circuit, protective device, UPS and earth bonding meet the installation design and applicable requirements.

In areas where supply continuity affects subscriber service, consider the entire power chain: grid availability, correctly sized UPS or battery system, upstream routing equipment, fiber terminal, backhaul radio and environmental cooling. Keeping only the switch energized will not preserve service if a required router or uplink device loses power. A realistic autonomy calculation should use verified equipment consumption and conversion losses rather than a switch-only headline. Ubiquiti lists maximum switch consumption at 30 watts excluding PoE output, so powered endpoint loads need to be incorporated separately. Project-specific electrical design should be reviewed by qualified personnel.

Environmental limits and cabinet protection

The published operating temperature range is minus ten to fifty degrees Celsius, with five to ninety-five percent noncondensing relative humidity. These are device operating limits, not a claim that the switch is weatherproof or suitable for direct unprotected outdoor exposure. Temperature inside a closed communications cabinet can differ significantly from ambient conditions, particularly under sunlight or when dense equipment produces heat. Select a suitable enclosure, protect equipment from water and dust as required by the site, and keep adequate airflow around installed components. Monitor the actual cabinet temperature where service reliability is important.

Ubiquiti also lists ESD and EMP protection figures for the unit, but those figures should not be represented as a complete lightning-protection solution. Outdoor Ethernet cables, radio masts and interbuilding links require a broader grounding, bonding and surge-risk assessment. Use appropriate protective equipment and installation practices for the site and the connected devices. In Tanzania, as in any deployment market, an installation plan should be aligned with applicable local electrical and building requirements. Do not infer a Tanzanian regulatory approval or site safety certification from international markings shown on a global product datasheet.

Where this switch fits particularly well

A useful deployment is a provider aggregation point where several 27V-compatible radios terminate on copper and a higher-capacity fiber path carries combined traffic toward upstream infrastructure. The sixteen powered ports can simplify the layout compared with scattered individual adapters, while eight further copper ports support devices that have their own power source. Another use case is a structured network room for a provider managing a cluster of access nodes and technical endpoints. The main attraction is not that every connection requires PoE, but that both powered and non-powered access links coexist with four flexible fiber interfaces in one managed unit.

This design is less attractive where most connected devices require IEEE-standard active PoE, where high-power endpoints exceed the per-port limit, or where the site needs more than 220 watts of aggregate passive power. It may also be unnecessary for a very small cabinet requiring only a few connections and one modest uplink. Buyers should compare realistic expansion and service requirements rather than selecting the largest port count by default. For an enterprise network with predominantly UniFi endpoints, also examine the operational benefits of selecting switches intended for the chosen management and power ecosystem.

Common mismatch: UISP versus UniFi

The product name can be confused with a UniFi Switch Pro, but the UISP Switch Pro is a separate device designed around the UISP product family. Its specified 27V passive-PoE outputs are materially different from the active PoE capability often associated with UniFi switching. A purchasing request that says only ’24-port Ubiquiti PoE switch’ is therefore not sufficiently precise. The equipment request should include the full model UISP-S-Pro, the required port mix, the intended endpoint power standards and the management environment. This simple step avoids expensive changes after a cabinet is wired.

Likewise, a 10G SFP+ uplink does not make a UISP device interchangeable with every similarly equipped UniFi switch. The operator should consider whether the objective is service-provider distribution, ordinary office access, Wi-Fi access-point aggregation or a mixed network. Requirements may differ for PoE negotiations, monitoring, firmware change control and technical staff familiarity. Where the network includes multiple product families, explicitly define the management boundaries and who supports each component. This makes procurement more reliable than choosing by appearance, front-panel port count or a shortened marketing name.

Preparing a precise purchasing specification

For a useful quotation, identify the complete product name and model, quantities needed and intended project timeline. Provide the number of powered endpoints and a device-by-device list of electrical requirements; specify which connections need data only. Include desired fiber uplink speeds, supported media, transceivers already owned and cable or cabinet constraints. If you already operate UISP, describe the application version and whether the installation must join an existing management environment. This information allows the seller or systems designer to flag mismatches before equipment is committed to the project.

Ask separately about regional stock status, final selling price, applicable taxes, delivery options and warranty terms rather than assuming that manufacturer information confirms local commercial conditions. These details can vary by listing and procurement date. Do not use a manufacturer product code as proof of a retailer’s internal SKU; that identifier must come from the exact local listing. A well-scoped request should also state whether the quotation needs compatible optics, fiber jumpers, rack accessories, UPS equipment, surge protection or installation services. No such accessory or service should be assumed included unless the final quotation explicitly says so.

Pre-deployment survey checklist

Before ordering, document the proposed rack and power arrangements, each device to be connected, cable distances, fiber routes and upstream traffic requirements. Verify whether existing patch panels and copper cabling are suitable for Gigabit operation and that the uplink has sufficient practical capacity. Count how many endpoints are ready for 27V passive input and how many need a different power method. Note which ports must remain available for future expansion. If a site has only limited maintenance access, account for remote-management reachability and the need for a safe recovery procedure when the main uplink fails.

Include an environmental review even for an indoor rack. Identify heat sources, ventilation paths, moisture exposure, grounding and surge-protection requirements. Confirm the appropriate installation method and available clearance for optics and cables. For any deployment where downtime affects paying customers, plan migration stages, configuration validation and a rollback option. This is not a promise that every issue can be avoided; it is a structured method for detecting the most common compatibility and site-readiness problems before the switching equipment becomes operational.

Staging and acceptance testing

A staged installation can start in a controlled workshop or maintenance window. Inspect the received model and accessories against the purchase order. Confirm that the intended management software recognizes the exact switch and that the firmware version is appropriate for the deployment. Establish a safe management configuration before connecting customer traffic. Connect test equipment to data-only ports first, then validate powered links individually with endpoints whose 27V compatibility is already documented. Record link state, successful boot behavior and observed traffic rather than treating a lit LED as complete proof of correct operation.

Test each planned fiber uplink with the actual transceiver and upstream device. Verify negotiated link speed and stable connectivity under realistic traffic. Check the site’s total intended PoE load and review whether any endpoint approaches the published per-port limit. Monitor equipment temperatures and power behavior where possible. An acceptance record should include serial numbers, rack locations, port mapping, cable identification, management access details held securely, and the person responsible for ongoing maintenance. Keep sensitive configuration material out of publicly accessible documentation.

Growth planning without overbuying

An aggregation switch is normally selected for both current traffic and plausible future expansion. Spare copper ports are useful when an access network adds radios or additional distribution links, and multiple SFP+ interfaces can help a network designer allocate high-capacity paths. Yet these spare interfaces do not substitute for adequate routing, fiber, power or site capacity. Project teams should forecast port use and wattage together. A growth plan that fills sixteen powered ports but ignores the 220W budget can be just as problematic as a plan that runs out of ports after installation.

Separate near-term additions from speculative longer-term requirements. Consider whether the next phase is likely to need another cabinet, an additional distribution switch, a change in radio power standards or a different uplink architecture. If a future endpoint family is expected to require active PoE or 48V power, the 27V output design should be reviewed before committing to a standard equipment build. Purchase decisions are strongest when capacity reserves, unit cost, support procedure and site constraints are considered together.

Operational maintenance and troubleshooting

Network teams should keep an accurate port map and a record of authorized changes to each site. When a powered endpoint stops responding, troubleshoot methodically: inspect the physical cable and connectors, check link state, verify the endpoint’s power specification, and review relevant management status. Never improvise by enabling passive PoE on an unknown device. If an uplink appears congested, compare measured traffic to negotiated link speed and inspect the rest of the upstream path. A switch with strong aggregate specifications can still be part of a network whose practical bottleneck sits elsewhere.

Define a repeatable process for maintenance windows, firmware updates, backup records and fault escalation. Keep spare transceivers, appropriate patch cords and any required field tools aligned with the installed equipment, not a generic shopping list. Secure administrative access and restrict who can modify port settings, especially those affecting power output. Clear operations documentation also helps when different technicians visit the site months apart. Reliable ongoing service depends on disciplined change management as much as it does on the hardware features stated on a datasheet.

Tanzania project considerations

For an operator planning service infrastructure in Tanzania, the most important local questions are practical: how the unit will be powered at the intended site, how upstream transport reaches the site, whether the cabinet can be maintained safely and whether replacement parts can be obtained through the chosen supply process. Conditions differ between buildings and locations, so avoid assumptions based on a national label alone. A rack installed in a controlled equipment room has different environmental and service-access considerations from equipment near an exposed rooftop radio route. Power continuity and surge management deserve particular scrutiny wherever an interruption would affect customer connections.

Confirm current availability, pricing in Tanzanian shillings, import-related commercial terms and any applicable local regulatory requirements with the parties responsible for the exact purchase and installation. The global Ubiquiti technical sheet establishes equipment characteristics, not a FourTeck Tanzania stock promise or proof of a particular local approval. The page therefore does not claim a local price, delivery timeline, warranty duration, service territory or installation entitlement. Share the intended topology and exact endpoint models when requesting a quote, so that procurement and engineering discussions refer to the same design.

Questions to settle before approval

First, verify that the connected equipment genuinely uses 27V passive PoE within its permitted input range and wiring requirements. Second, calculate worst-case power consumption against both the 30W individual port ceiling and the 220W total. Third, decide how many of the four SFP+ interfaces are required immediately and confirm the optical modules and upstream equipment. Fourth, determine whether the intended management workflow uses UISP and whether the current software release supports the planned setup. Fifth, make sure the rack, electrical provision and environmental conditions suit the installed unit. These checks collectively provide a much stronger purchase basis than port count alone.

Ask what happens if the main power feed or fiber uplink fails, and whether the wider network has an appropriate resilience plan. Confirm that safe access, cable labelling and maintenance records will be available after commissioning. Finally, compare the total project cost, including necessary optics, protection and power accessories, against alternatives that may have a different PoE architecture. The UISP Switch Pro offers a defined combination of passive-power access ports and fast fiber interfaces; the right choice depends on matching that combination to the actual equipment and service topology.

Frequently asked questions

Does the UISP Switch Pro have twenty-four PoE ports? No. It has twenty-four Gigabit copper ports, of which sixteen are specified for 27V passive PoE. The other eight are not part of that powered-port group. Can it power any PoE access point? No. Verify the exact endpoint voltage, pin configuration and passive-versus-active PoE requirements. What is the maximum PoE allowance? The manufacturer states 220W total and 30W maximum per powered port, so both limits apply. Are the uplinks all 10G only? Ubiquiti identifies four 1/10G SFP+ ports; verify transceivers and peer devices for the intended negotiated speed.

Is the switch managed by UniFi Network? The published management platform is UISP, beginning with application version 1.5.7. Do not assume native UniFi Network adoption. Does the device include an electrical backup system? The published specification shows AC and DC inputs, but redundancy behavior and the required supporting equipment must be verified in the installation documentation. Can it be installed outdoors? The published operating limits do not establish an outdoor weatherproof enclosure rating; use a suitable protected installation. Is there a confirmed Tanzania price or stock status? No local selling price or availability has been verified for this content. Request a quotation for the exact model and required accessories.

Request a project-specific quotation

The Ubiquiti UISP Switch Pro (UISP-S-Pro) is best evaluated as part of a complete network design, not as an isolated item. Its twenty-four Gigabit copper ports, sixteen 27V passive-powered connections and four 1/10G SFP+ uplinks can make it a useful candidate for provider aggregation when power compatibility and throughput needs are aligned. The decisive detail is whether the connected endpoint inventory fits its precise electrical and management specification. An accurate bill of materials should therefore be built before purchase rather than assuming every PoE-labelled device can share the same power arrangement.

To discuss this model for a Tanzania network project, request a FourTeck Tanzania quotation with the planned number of connections, radio or endpoint model list, expected power draw, uplink type and site constraints. Ask for confirmation of the exact product configuration, any required accessories and current commercial terms. Where the design uses a different PoE voltage or management platform, say so explicitly so the proposed switch can be evaluated against a more suitable alternative. A clear technical scope is the best starting point for a responsible purchase.

Reviews

There are no reviews yet.

Be the first to review “Ubiquiti UISP Switch Pro UISP-S-Pro”

Your email address will not be published. Required fields are marked *

Scroll to Top
Powered by Joinchat